IMPORTANT
Prepare Xprecia
System(s)PTControls in advance and allow to stand for 5 minutes. Use the reconstituted control solution within 25 minutes, when stored at
15–25°C (59–77°F). For complete instructions, see the XpreciaStrideUserGuide and the instructions for use that came with your controls.
Patient Test
Quality Control Test
Seings
Recall Results
Seings – Icon Key
Clock
Change the time.
Date
Change the date.
Analyzer
Customize the volume, brightness, baery type,
default seings, and how results are displayed.
Language
Change your language seings.
Information
View the software version number.
Tutorial
Learn how to perform a patient test,
QC test, or hold Stride.
Administrator
Customize the administrator seings for optional
Operator ID (OID), Patient ID (PID), and Login.
Reference Information
For complete cleaning instructions,
see the XpreciaStrideUserGuide
siemens.com/healthineers
Xprecia Stride
Coagulation Analyzer
For complete instructions, see the XpreciaStrideUserGuide and the instructionsforuse that came with your test strips and controls.
1. Scan Patient ID
(optional)
2. Scan strip 3. Insert strip 4. Scan strip vial
(for new lot
number)
5. During warm up,
prepare patient
for fingerstick
6. Hold level 7. Apply sample 8. Test in progress 9. View result 10. Eject strip 11. Clean Stride
1. Scan control
solution bole
2. Scan strip 3. Insert strip 4. Scan strip vial
(for new lot
number)
5. Gather controls 6. Hold level 7. Apply control
sample
8. Test in progress 9. View result 10. Eject strip 11. Clean Stride
1. Tap a result type 2. Tap a result to
view details
3. Tap to view
more details
Question and Answer IconNeed help?

Do you have a question about the Siemens Xprecia Stride and is the answer not in the manual?

Siemens Xprecia Stride Specifications

General IconGeneral
BrandSiemens
ModelXprecia Stride
CategoryMeasuring Instruments
LanguageEnglish

Summary

Patient Test Procedure

Scan Patient ID

Scan patient identification to associate test results with the patient.

Scan Test Strip

Scan the test strip barcode for lot information and compatibility.

Insert Test Strip

Insert the test strip into the designated slot on the analyzer.

Scan Test Strip Vial

Scan the test strip vial barcode for new lot numbers.

Prepare for Sample

Prepare the patient for sample collection during analyzer warm-up.

Hold Analyzer Level

Hold the analyzer level during sample application for accurate results.

Apply Patient Sample

Apply the patient sample to the test strip.

View Test Progress

Monitor the test progress on the analyzer screen.

View Test Result

View the final test result displayed on the analyzer.

Eject Test Strip

Eject the used test strip from the analyzer.

Clean Analyzer

Perform cleaning procedures after test completion.

Quality Control Test Procedure

Scan Control Solution Bottle

Scan the control solution bottle barcode for identification.

Scan Control Strip

Scan the test strip barcode for control testing.

Insert Control Strip

Insert the test strip into the analyzer for control testing.

Scan Control Strip Vial

Scan the strip vial for new lot numbers for control solutions.

Gather Control Solutions

Prepare and gather the necessary control solutions.

Hold Analyzer for Control

Hold the analyzer level during control sample application.

Apply Control Sample

Apply the control sample to the test strip.

View Control Test Progress

Monitor the control test progress on the analyzer screen.

View Control Test Result

View the control test result displayed on the analyzer.

Eject Control Strip

Eject the used control test strip from the analyzer.

Clean Analyzer After QC

Perform cleaning procedures after completing quality control tests.

Analyzer Settings and Information

Settings Icon Key

Explains the icons used within the analyzer's settings menu.

Clock Settings

Allows adjustment of the analyzer's internal clock time.

Date Settings

Allows adjustment of the analyzer's internal date.

Analyzer Customization

Customize analyzer volume, brightness, and default settings.

Administrator Settings

Customize administrator settings like Operator ID (OID) and Patient ID (PID).

Language Settings

Change the language displayed on the analyzer.

Software Information

View the current software version number of the analyzer.

Tutorial Access

Access tutorials for performing various tests on the analyzer.

Recall Results

Select Result Type

Tap a result type to initiate the recall process.

View Result Details

Tap a specific result to view its detailed information.

Access More Details

Tap again to view further details of the selected result.