42
NX-1700
NX-1700 DC NX-2700
[PN 200863]
[PN 200464] [PN 200401]
Capacity WANCapacity
(AllFeatures)
4 Mbps 4 Mbps 10 Mbps
LocalDataStore 1 x 240 GB HDD 1 x 500 GB HDD 2 x 500 GB HDD
Connectivity LAN/WAN
Ethernet
4 x 10/100/1000 LAN WAN
2 x 10/100/1000;
RJ-45 serial port
4 x 10/100/1000 LAN WAN 4 x 10/100/1000 LAN WAN
Management
2 x 10/100/1000;
RJ-45 serial port
2 x 10/100/1000;
DB-9 serial port
2 x 10/100/1000;
DB-9 serial port
Power Requirement
100–240VAC 50–60Hz,
23 W / 78.5 BTU
-31VDC to -72VDC,
86 W / 295 BTU
100–240VAC 47-63Hz,
285 W / 973 BTU
Dimensions &
Weight
PowerSupplies
Single (Power Adapter)
Single 1+1 redundant
Height 1.73 in. (44 mm) 1.8 in. (45 mm) 1 RU 3.5 in. (89 mm) 2 RU
Width 9.45 in. (240 mm) 17.5 in. (445 mm) 16.9 in. (430 mm)
Depth 6.54 in. (166 mm) 8.2 in. (209 mm) 26 in. (660 mm)
Weight 3.0 lbs (1.4 kg) 8.5 lbs (3.9 kg) 40.5 lbs (18.4 kg)
NX-2700 NX-2700 NX-3700
[PN 200697] [PN 201020] [PN 200400]
Capacity WANCapacity
(AllFeatures)
10 Mbps 10 Mbps 20 Mbps
LocalDataStore 2 x 240 GB SSD 2 x 480 GB SSD 2 x 500 GB HDD
Connectivity LAN/WAN
Ethernet
4 x 10/100/1000 LAN WAN 4 x 10/100/1000 LAN WAN 4 x 10/100/1000 LAN WAN
Management 2 x 10/100/1000;
DB-9 serial port
2 x 10/100/1000;
DB-9 serial port
2 x 10/100/1000;
DB-9 serial port
Power Requirement 100–240VAC 50-60Hz,
94 W / 321 BTU
100–240VAC 50-60Hz,
80 W / 273 BTU
100–240VAC 47-63Hz,
305 W / 1041 BTU
Dimensions &
Weight
PowerSupplies 1+1 redundant 1+1 redundant 1+1 redundant
Height 1.69 in. (43 mm) 1 RU 1.68 in. (42.8 mm) 1 RU 3.5 in. (89 mm) 2 RU
Width 17.1 in. (434 mm) 17.1 in. (434 mm) 16.9 in. (430 mm)
Depth 26.1 in. (663 mm) 24 in. (610 mm) 26 in. (660 mm)
Weight 24.0 lbs (10.8 kg) 23.5 lbs (10.7 kg) 40.5 lbs (18.4 kg)