EasyManua.ls Logo

Silver Peak EC-US - Using Appliance Manager

Silver Peak EC-US
188 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Silver Peak Hardware Reference Guide
Copyright © September 2018 by Silver Peak Systems, Inc. All rights reserved
8
Using Appliance Manager
Physical appliances have redundant encrypted disks.
Disk failure results in a critical alarm, and the specific disk’s LED stops illuminating on the appliance.
To replace a failed disk:
1. Log into your Support portal account, and click Open a Self Service RMA for disk replacement.
2. Complete the wizard, using the serial number of the appliance (not the disk).
3. After you receive the new disk, go to the Maintenance - Disk Management page.
4. Select the failed disk's row in the table and click Remove. This takes the disk off-line.
5. Physically remove the old disk from the appliance.
6. Physically insert the new disk.
7. In the table, select the new disk and click Insert. This prompts the software to discover the disk and put it
online.

Table of Contents

Related product manuals