3 Selection of parameters for standard control unit
FX2004 - FX5100 (C0 = 0.00)
P1 conveying time (10.0)
P1 = X.XX X.XX sec. conveying time
Works setting: 10.0 sec.
P2 mixture ratio (0.00)
P2 = X.XX X.XX % mixture ratio
Ratio of new material to regenerated material.
Set value = volume of regenerated material in %
Residual value = new material in %
Works setting: 0.00
(= 100 % new material; no regenerated material).
Example: Set value = 80
Î80 % regenerated material; 20 % new material.
P3 pause time (0.00)
P3 = X.XX X.XX sec. pause time
until conveying is continued after the flap closes.
Works setting: 0.00 sec.
P4 emptying suction time 1 (0.00)
P4 = X.XX X.XX sec. emptying suction time 1
At the connection for regenerated material
Works settings: 0.00 sec.
P5 emptying suction time 2 (0.00)
P5 = X.XX X.XX sec. emptying suction time 2
At the connection for new material
Works settings: 0.00 sec.
P6 reserve (0.00)
P6 = X.XX Reserve; no function
The programming mode is quit on pressing the ON/OFF key once and the unit
switches to standby mode.
P-parameters are entered between 0.0 and 600.