1.3 GENERAL DATA
MODE OUTPUT INPUT (G.C.V.)
BURNER PRESS. (Nat. gas)
BURNER PRESS. (Butane/Propane)
kW Btu/h kW Btu/h mbar inwg mbar inwg
CENTRAL HEATING RANGE 9.0 31,000 12.0 42,000 2.4 0.9 5.9/7.7 2.4/3.1
10.6 36,000 14.1 48,000 3.2 1.3 7.9/10.3 3.2/4.1
12.3 42,000 16.2 55,000 4.1 1.7 10.2/13.2 4.1/5.3
14.1 48,000 18.2 62,000 5.2 2.1 12.7/16.3 5.1/6.5
X* (G20-G31) 15.9 54,000 20.3 69,000 6.3 2.5 15.4/19.6 6.2/7.9
X* (G30) 17.7 60,000 22.4 76,000 7.5 3.0 18.4/23.2 7.4/9.3
19.6 67,000 24.5 84,000 8.9 3.6 21.5/26.9 8.6/10.8
21.5 73,000 26.6 90,000 10.3 4.1 24.8/30.8 10.0/12.4
23.4 80,000 28.7 98,000 11.8 4.7 28.5/36.5 11.4/14.7
DOMESTIC HOT WATER Max. 23.4 80,000 28.7 98,000 11.8 4.7 28.5/36.5 11.4/14.7
Min. 9.0 31,000 12.0 42,000 2.4 0.9 5.9/7.7 2.4/3.1
* Factory setting
TABLE 3a - Nominal boiler ratings (5 minutes after lighting) for “FORMAT 80 C”
MODE OUTPUT INPUT (G.C.V.)
BURNER PRESS. (Nat. gas)
BURNER PRESS. (Butane/Propane)
kW Btu/h kW Btu/h mbar inwg mbar inwg
CENTRAL HEATING RANGE 11.4 39,000 15.0 51,000 2.6 1.0 5.5/7.1 2.2/2.9
13.5 46,000 17.5 60,000 3.5 1.4 7.4/9.4 3.0/3.8
15.6 53,000 20.0 68,000 4.5 1.8 9.7/12.1 3.9/4.8
17.7 60,000 22.5 77,000 5.6 2.3 12.2/14.9 4.9/6.0
X* (G20-G31) 19.8 68,000 25.0 86,000 6.8 2.7 14.9/18.0 6.0/7.2
X* (G30) 22.0 75,000 27.6 94,000 8.2 3.3 17.9/21.3 7.2/8.6
24.2 83,000 30.1 103,000 9.6 3.8 21.2/24.8 8.5/10.0
26.5 90,000 32.6 111,000 11.1 4.5 24.7/28.5 9.9/11.4
28.8 98,000 35.1 120,000 12.7 5.1 28.5/36.5 11.4/14.7
DOMESTIC HOT WATER Max. 28.8 98,000 35.1 120,000 12.7 5.1 28.5/36.5 11.4/14.7
Min. 11.4 39,000 15.0 51,000 2.6 1.0 5.5/7.1 2.2/2.9
* Factory setting
TABLE 3b - Nominal boiler ratings (5 minutes after lighting) for “FORMAT 100 C”
MODE OUTPUT INPUT (G.C.V.)
BURNER PRESS. (Nat. gas)
BURNER PRESS. (Butane/Propane)
kW Btu/h kW Btu/h mbar inwg mbar inwg
CENTRAL HEATING RANGE 11.2 38,000 15.0 51,000 2.2 0.9 4.5/5.8 1.8/2.3
13.6 46,000 17.9 61,000 3.1 1.3 6.4/8.2 2.6/3.3
16.0 55,000 20.9 72,000 4.2 1.7 8.5/11.0 3.4/4.4
18.5 63,000 23.9 81,000 5.4 2.2 11.0/14.1 4.4/5.7
X* (G20-G31) 21.0 72,000 26.8 92,000 6.8 2.7 13.7/17.6 5.5/7.1
X* (G30) 23.6 80,000 29.8 101,000 8.3 3.3 16.7/21.4 6.7/8.6
26.2 89,000 32.7 111,000 10.0 4.0 20.0/25.6 8.0/10.3
28.9 99,000 35.7 122,000 11.8 4.7 23.5/30.0 9.4/12.0
31.6 108,000 38.6 132,000 13.7 5.5 28.2/36.2 11.3/14.5
DOMESTIC HOT WATER Max. 31.6 108,000 38.6 132,000 13.7 5.5 28.2/36.2 11.3/14.5
Min. 11.2 38,000 15.0 51,000 2.2 0.9 4.5/5.8 1.8/2.3
* Factory setting
TABLE 3c - Nominal boiler ratings (5 minutes after lighting) for “FORMAT 110 C”