Features
Emergency voice/alarm communications provide:
Alarm/evacuation signal generation with multiple
built-in tones
Standard or customized digital message storage and
message generation
Automatic or manual operation
Mass Notification operation
Multiple channels are available:
Analog audio systems provide dual channel operation
Digital audio systems provide up to eight channels over
a single wire pair
Communications features:
Up to five supervised remote microphone inputs
Spoken voice coding from the digital message player
Multiple digitally recorded human voice messages
Spoken WALKTEST system testing
Separate evacuation, drill, and optional “All Clear”
voice messages and tones
Ready-to-talk microphone indicator on front panel audio
control module
Local panel speaker for tone/message broadcast
verification
MINIPLEX Voice Transponders are available for
distributed audio
Amplifiers are available with analog or digital input:
Flex-35 (35 W) and Flex-50 (50 W) amplifiers provide a
dual channel design with configurable operation modes
100 W primary and backup, single channel amplifiers
include a built-in power supply
Amplifiers are available for 25 VRMS or 70.7 VRMS
output with on-board, power-limited NACs (only one
voltage choice per system)
Built-in Temporal Pattern horn tone provides default
backup signal operation
Optional modules provide power-limited NAC expansion,
convert Class B NACs to Class A operation, and provide
Constant Supervision Operation for Non-Alarm Audio
(NAA) applications (NAA requires additional hardware,
and software revision 11.08 or higher)
Firefighter telephone systems:
Master telephone can simultaneously talk with up to 6
remote telephones and can be connected as an audio
input for broadcast messages
Ring signal on remote firefighter telephone indicates that
a call request is initiated and a hold signal indicates that
a connected line has been deselected
Telephone circuits are supervised for open and short
circuits, too many telephones connected, and the master
telephone is supervised for cord integrity
Degraded mode allows remote telephones to remain
connected to each other in the event of a communications
loss
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
Press ACK located under flashing indicator.
Repeat oper atio n unti l a ll ev ents are a ckno wle dged .
Local tone will sil ence.
A B C
AC Power
D E F G H I
J K L M N O P Q R
'SP' ( ) , 0 :
S T U V W X Y Z /
ALARMS
Fire Alarm Priority 2 Alarm
SYSTEM WARNINGS
Supervisory Trouble Alarm Silenced
Emergency Operating Instructions
Alarm or Warning Condition
How to Acknowledge / View Events
How to Silence Building Signals
System indicator flashing. Tone On. Press Alarm Silence.
How to Reset System
Press System Rese t.
Press Ack to silence tone device.
ZONE
1
SIG
2
AUX
3
FB
4
IO
5
IDNet
6
P
7
A
8
L
9
NET ADDR
0
DEL
Enter C/Exit
Fire Alarm
Ack
Priority 2
Ack
Supv
Ack
Trouble
Ack
Alarm
Silence
System
Reset
Event
Time
Enable
On
Arm
Disable
Off
Disarm
Auto
Lamp
Test
More
Info
Menu
Previous
Next
4100ES Fire Alarm Control Panel with
Voice and Firefighter Telephone Options
Listed to:
UL Std. 864, Fire Detection and Control (UOJZ), and
Smoke Control Service (UUKL)
UL Std. 2017, Process Management Equipment (QVAX)
UL Std. 1076, Proprietary Alarm Units-Burglar (APOU)
UL Std. 1730, Smoke Detector Monitor (UULH)
ULC Std. S527-99
Description
4100ES Audio Systems provide voice communication,
alarm tones, and/or digitally prerecorded voice messages to
alert occupants of fire or other emergency situations.
Evacuation signaling may be automatically generated via
alarm initiated event programs or by firefighting personnel
using the operator controls.
4100U Series Products Note. The audio system
modules and features listed in this data sheet are both
compatible with, and listed for use with 4100U series fire
alarm control panels. Contact your local Simplex
®
product
supplier for details.
* See page 5 for product that is listed as UL or ULC and additional product listing details.
This product has been approved by the California State Fire Marshal (CSFM) pursuant to
Section 13144.1 of the California Health and Safety Code. See CSFM Listing
7165-0026:251 for allowable values and/or conditions concerning material presented in this
document. It is subject to re-examination, revision, and possible cancellation. Accepted for
use – City of New York Department of Buildings – MEA35-93E. Additional listings may be
applicable; contact your local Simplex product supplier for the latest status. Listings and
approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection
Products.
Fire Control Panels
UL, ULC, CSFM Listed; FM Approved; Addressable Fire Detection and Control
MEA (NYC) Acceptance* Emergency Voice/Alarm Communications Equipment
S4100-0034-12 3/2012