STORING THE PRESSURE WASHER
The pump on this unit is a maintenance free design. The pump was lled with oil at the
factory and has no oil drain or ll plugs. If there is a problem with the pump on this pressure
washer call 1-877-362-4271 or email cservice@fna-group.com.
Pump Maintenance
1. Disconnect the high-pressure hose from the pump and the gun.
2. Hold the gun in a vertical plane and squeeze the trigger to remove trapped water.
3. Remove trapped water from the high-pressure hose; coil for storage.
4. Using SIMPSON Pump Guard*, attach the nozzle hose to the pump input.
5. Push down on the Pump Guard nozzle unit the excess water and protectant
comes out of the high-pressure port. Disconnect the Pump Guard connector.
6. Store the pressure washer and its accessories in a cool, dry location out of direct
sunlight.
* SIMPSON Pump Guard (not included) is the best way to maintain the health of your high-
pressure pump. It lubricates and protects the seals during long-term storage while lling
the pump with a non-freezing solution. Never allow water to remain within the pump during
storage. The water will freeze if the temperature dips below 33
o
F (0.6
o
c), damaging your
pump and voiding its warranty.
PRODUCT SPECIFICATIONS
Peak Pressure
Peak Water Flow
2300 PSI
1.2 GPM
Water Supply Temperature 41
o
F (5
o
c) - 90
o
F (32
o
c)
Motor Induction Type
Rated Voltage 120v AC, 60 Hz
Current 13 Amperes
Values are within manufacturing tolerance of +/- 10%