Failure to read and follow the operators manual and all of its instructions before using
the product could result in DEATH or SERIOUS INJURY. Read this manual carefully and
become failure with your electric pressure washer. Know its applications, its limitations
and any hazards involved.
OPERATOR SAFETY
WARNING:WARNING:
Improper connection of the equipment grounding conductor can result in the risk of
electrocution. Check with a qualied electrician if you are in doubt as to whether the
receptacle is properly grounded. DO NOT modify the plug provided with this product. If
it will not t the receptacle, have a proper receptacle installed by a qualied electrician.
DO NOT use any type of adapter with this product.
ELECTROCUTION HAZARD
Page 4
This pressure washer is provided with a ground fault circuit interrupter (GFCI) built into the
plug of the power supply cord. This device provides additional protection from the risk of
electric shock.
Ground Fault Circuit Interrupter Protection
Should replacement of the plug or cord becomes necessary, use only identical replacement
parts that include GFCI protection.
Grounding Instructions
This pressure washer must be grounded. If it should malfunction or breakdown, grounding
provides a path of least resistance for electric current to reduce the risk of electric shock.
This product is equipped with a cord that contains an equipment grounding conductor and
a grounding plug. The plug must be connected to an appropriate receptacle that is properly
installed and grounded in accordance with all local codes and ordinances.
DANGER:DANGER:
Thermal Relief Valve
When the temperature inside the pump rises to a predetermined setting, this valve will open
allowing the hot water to exit and cool water to enter, cooling the pump. The value will then
close.
Motor Overload
The electric motor in this pressure washer is equipped with an thermal overload protection
device. This device will automatically shut o󰀨 the motor if the motor overheats or draws
too excessive current. If the overload protection is tripped, turn the power o󰀨 by turning
the master ON/OFF switch to the OFF (0) position. Let the unit cool for thirty (30) minutes.
After the unit has cooled, turn the master ON/OFF switch to the ON (l) position to resume
operation.