Simrad EQ60
132
857-164342 / Rev.C
Cable specifications
The cables identified in the cable plan are listed here. Each
cable is identfied with a cable number and a type number.
Basic configuration
ID Typ e Specifications Use MFD
C1 W103 Page 142 / Note 1 S e r i a l l i n e 1 , c o n n e c t s t o 9 --- p i n D --- s u b
C2 W103 Page 142 / Note 1 S e r i a l l i n e 2 , c o n n e c t s t o 9 --- p i n D --- s u b
C3 W505 Page 148 Standard Centronics printer cable
C4 W301 Page 144 AC power Yes
C5 W620c Page 152 / Note 2 Heave & temperature sensors
C6 W620b Page 151 / Note 2 External synchronization
C7 W806 Page 161 Transducer(s) Yes
C8 W311 Page 143 Ship’s ground
C9 W511 Page 149 / Note 3 Mouse Yes
C10 W511 Page 149 / Note 3 Keyboard Option
Note 1 - The number of serial lines depends on how many
communication ports that are installed.
Note 2 - These interfaces are both connected to the Auxiliary
plug on the echo sounder unit.
Note 3 - The rollerball and the keyboard shares the same PS/2
connector on the echo sounder by means of an adapter. The
adapter is a part of the system delivery.