Cable layout
157
857-164342 / Rev.C
Dual frequency, single beam
The drawing shows how to connect a dual frequency, single
beam transducer to the system.
M
E
F
J
H
D
C
K
L
A
B
N
W802-4 / Rev.C
Dual frequency, single beam
Dual frequency,
single beam
transducer
C
H
D
J
GPT
Inner
screen
Outer
screen
Junction Box (1:1)
Low frequency
High frequency
Note:
1) All transducer cables must be run in
steel conduits. Use flexible conduit closer
to the transceiver.
2) Cable shields must be connected to
the plug housing.
3) Cable shields must be connected to
ship's ground in the junction box.
not
Plug housing
Conductors 2x2xNmm2
Screen Overall braided
Voltage 60 V
Max.diameter N/A
The conductor diameter “N” depends on the chosen transducer.
Normal value for single beam transducers is 1.5 mm
2
.Special
transducer cable is available from Simrad.