EN
3.1 Changing the output volume of the SSV metering
devices
About 0.2 cc of lubricant are supplied per stroke and
outlet. Closing unneeded outlets with closure screws
(7.2) increases the output of the next lower open outlet
on the same side by the lubricant volume of the upper
closed outlets. Maximum number of outlets that can
be crossported internally is 4 with the TLMP 1008 and
9 with the TLMP 1018.
Adjust output on SSV metering device Fig. 3
7.2
7
5
3
1
8
6
4
2
1x
2x
1x
3x
1x
7.2