29
4
EN
Pump variant
24 V DC 120 V AC
60 Hz
230 V AC
50 Hz
Power supply with square plug (left side) yes yes yes
Tolerance of input voltage -20 / + 30 % ±10 % ±10 %
Current input (maximum) ≤ 1 A ≤ 1 A ≤ 0.5 A
Types of protection PELV
Inputs protected against reverse polarity, short circuit proof, non-isolated
Fault signals with square plug (right side) yes yes yes
Protective and disconnecting device required for isolation yes yes yes
Switching voltage 48 V AC / DC 48 V AC / DC 48 V AC / DC
IP protection class of bayonet plug 65 65 65
AC fault relay for low level signal and fault signals 230 V AC 230 V AC 230 V AC
maximum switched current 5 A 5 A 5 A
DC fault relay for low level signal and fault signals 24 V DC 24 V DC 24 V DC
maximum switched current 5 A 5 A 5 A
Residual ripple (DIN 41755) ±5 % ±5 % ±5 %
#
IP 67 only for square plugs with prefabricated cable
4.2 Electrics
4. Technical data