SJ45 AJ+, SJ60 AJ+ 238264AAA
31
Features and devices Section 3 – Familiarization
FAMILIARIZATION
3.4-6 Function restrictions when the MEWP is tilted
Mode/Condition
Indicator
Light
Audible Alarm Restrictions
Emergency Power
(Platform)
Emergency Power
(Base)
Lowered travel position, tilted Disabled Disabled No restriction Enabled Enabled
In lowered travel position, tilted,
moving into elevated travel
position (at the limits of the lowered
travel position)
Enabled Enabled
Boom Extension,
Boom Up, and
Riser Up disabled
Enabled Enabled
Elevated travel position, tilted Enabled Enabled Drive disabled Enabled Enabled
1880AA
NOTE
If you reset power to the controls (i.e. push and pull the emergency-stop button) when the MEWP is tilted, and
at the limits of the lowered position, the MEWP will be in the “tilted while elevated” condition.
3.4-7 Overload status - SJ45 AJ+
Mode/Condition
Indicator
Light
Audible
Alarm
Drive
Functions
Powered
Boom
Functions
Emergency
Power
(Platform)
Emergency
Power
(Base)
The platform is near the rated load On Off Enabled Enabled Enabled Enabled
In the lowered travel position: the load on the
platform is more than the rated load
Flashing Pulsing Enabled Enabled Enabled Enabled
In the elevated travel position: the load on the
platform is more than the rated load
Flashing Pulsing Disabled Disabled Enabled Enabled
2095AA
* If you reset power to the controls (for example, push and pull the emergency-stop button) when the
MEWP is in this mode, the MEWP will be in the overload condition when elevated.
WARNING
If the platform load sensing system is in the fault mode, the overload light flashes. Do the steps that follow:
Make sure the platform is level, and there are no obstructions in contact with the platform.
If the platform load sensing system stays in the fault mode, the emergency-power unit can be used
to lower the platform. Remove the MEWP for servicing. Speak to a qualified service technician for
repairs. If you do not obey, there is a risk of death or serious injury.
To order go to Discount-Equipment.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ60 AJ+ and is the answer not in the manual?

Skyjack SJ60 AJ+ Specifications

General IconGeneral
BrandSkyjack
ModelSJ60 AJ+
CategoryBoom Lifts
LanguageEnglish

Related product manuals