Table 15.47. 0x0145 Power Down All Outputs
Reg Address Bit Field Type Setting Name Description
0x0145 0 R/W OUT_PDN_ALL 0- no effect
1- all drivers powered down
Si5391 Reference Manual • Si5391A/B Register Map
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
77 Rev. 0.5 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 11, 2022 77