5
5693
21 2023
-
SE60/185 s2
MC_0127
Product Measurements
Measurement
code
Measurement description
mm inch mm inch
ID Internal tunnel diameter 185 7.3 185 7.3
H Motor Height 272 10.7 250 8.1
W Width 199 7.8 201 7.9
L Length 208 8,19 205 8.1
WD Water Depth 185 7.3 185 7,28
TL Minimum tunnel length 128 5 128 5,04
TL (recommended) Recommended tunnel length 165 6.5 165 6,50
T (min) Minimum tunnel wall thickness 4 0.16 4 0.16
T (max) Maximum tunnel wall thickness 6 0.24 6 0.24
SE60 s2
12v
SE60 s2
24v
*Valid for SE & SEP
MC_0137
Product Specifi cations
* SE and SE-IP are measured at motor terminals when the thruster is operated for on/off thrusters
Product Maximum Operating Voltage* Thrust is kg / lbs at (V)
Power Output
kW / Hp
Weight
kg / lbs
Maximum Operation Time
SE60 12V 12V 73 kg / 161 lbs (12V) 60 kg / 132 lbs (10.5V) 3.1 kW / 4 hp 16 kg / 35 lbs
S2 motor at 2 - 3 min.
Duty cycle at 20°c
(Ambient temperature)
SE60 24V 24V 73 kg / 161 lbs (24V) 60 kg / 132 lbs (21V) 3.1 kW / 4 hp 16 kg / 35 lbs