Electrical Connection SMA Solar Technology AG
32 WB33_38-IEN101830 Installation Guide
5.5.4 Connecting the Small Wind Turbine System (DC)
1. Check the DCplugconnectors for correct polarity and connect them to the inverter. To release
the DC connectors see section 7.2”Opening the Inverter” (page44).
2. To create the seal on the inverter, all DC inputs that
are not required must be closed as follows:
Insert the sealing plugs provided into the
DCplug connectors that are not needed.
Donot insert the sealing plugs into the
DCinputs on the inverter.
Insert the PV connectors with sealing plugs into
the corresponding DC inputs on the inverter.
The small wind turbine system is connected.
You can now commission the inverter as described
in section 6”Commissioning” (page36). The
following connection options are optional.
DANGER!
Danger to life due to high voltages in the inverter.
Before connecting the small wind turbine system, ensure that the
smallwindturbinesystem is stopped.