T4 (053B) Series Installation Guide
CD354/220116 Smartscan Ltd
Status Indicators
LEDs for status indication and diagnostics are located in the top of the Transmitter
(TX) head and Receiver (RX) head. In addition the Receiver (RX) head has six
LEDs at the bottom located inside the housing to aid DIP switch setting. To aid
configuration each DIP switch has a corresponding colour LED to acknowledge
activation of the individual DIP switch.
Receiver (RX) Top
ON – GREEN LED on = OSSDs in the on state
OFF – RED LED on = OSSDs in the off state
LO1 (Lockout 1) – YELLOW LED on = OSSD fault
LO2 (Lockout 2) – YELLOW LED on = Mute disparity fault (MU1 & MU2)
EDM (External Device Monitoring) – YELLOW LED on = EDM on
Receiver (RX) Bottom
LEDs located on the DIP switch board are accessed via a cap on the side of the
extrusion. (Ensure that the cap is securely in place to maintain IP integrity after
use).They are used to show the status of each individual DIP switch. LED on
equals DIP switch in the ‘ON’ position, LED off equals DIP switch in the ‘OFF’
position.
DIP switch 1 = Red LED
DIP switch 2 = Yellow LED
DIP switch 3 = Green LED
DIP switch 4 = Blue LED
DIP switch 5 = Red LED
DIP switch 6 = Orange LED
Transmitter (TX) Top
PWR (Power) - RED LED on = Power connected
STAT (Status) - GREEN LED on = Alignment ok
MUT (Muted) – YELLOW LED on = Muted
MU1 (Mute1) – BLUE LED on = Mute 1 on
MU2 (Mute2) – BLUE LED on = Mute 2 on