- 12 -
The following operation types are available by setting P_1 and P_2.
(Note) This function is available for monitor output: switch output type. (ITVX2030-2, -3)
P_1P_2 P_1P_2
Window comparator mode Hysteresis mode
ON
OFF
P_1
P_2
ON
OFF
P_1
P_2
P_1P_20 Out of range mode
(The switch output turns on when set pressure is achieved.)
ON
OFF
Reset function
Switch output
Output pressure of
E/P regulator
Input signal
Output pressure of
E/P regulator
Switch output