CW/CWH–511MDA
5
2 TECHNICAL DATA
Supplyvoltage V 230V
Frequency Hz 50
Max.powerabsorptionat230V1N~ kW 3.5
Boilerheatingelementpowerat230V1N~ kW 2.8
Tankheatingelementpower kW 0,8
Waterintakepressure kPa(bar) 100‐600(1÷6)
Waterintaketemperature °C 15°C–60°C
Intakewaterhardness(modelswithsoftener) °f 15°f‐60°f
Rinsecyclewaterconsumption l 3.2
Boilercapacity l 6
Tankcapacity l 11
Standardcycledurationwithintakewaterat50°C S 90/120/180
Noiselevel dB(A) 50
Degreeofprotection IPX 4/5
Netweight Kg 60/63(CW)
79/82(CWH)
Powersupplycabletype ◄HAR► H07RN‐F
Fuse A 4
THESYMBOLOFTHERUBBISHBINWITHABARACROSSITONTHEPRODUCTORINTHE
TECHNICALDOCUMENTATIONINDICATESTHATTHISPRODUCTMUSTNOTBETREATED
ASORDINARYDOMESTICWASTEBUTMUSTBECONSIGNEDTOTHESPECIAL
COLLECTIONPOINTFORTHERECYCLINGOFELECTRICALANDELECTRONICEQUIPMENT.
NEVERPLACESOLVENTSSUCHASALCOHOLORTURPENTINE,WHICHMIGHTCAUSEAN
EXPLOSION,INSIDETHEAPPLIANCE.NEVERLOADDISHESDIRTYWITHASH,WAXOR
PAINTS.
NEVERUSETHEWAREWASHERORANYPARTOFITASALADDER,SUPPORTORSTAND
FORPEOPLE,ANIMALSORANYOBJECT.
LEANINGORSITTINGONTHEOPENDOOROFTHEWAREWASHERMIGHTCAUSEITTO
TIPOVER,PUTTINGPEOPLEINDANGER.
NEVERLEAVETHEWAREWASHERDOOROPENSINCEPEOPLEMIGHTTRIPOVERIT.
DONOTDRINKANYWATERLEFTINTHEDISHESORWAREWASHERATTHEENDOFTHE
WASHINGPROGRAM.
THEAPPLIANCEISNOTSUITABLEFORUSEBYJUVENILESORPERSONSWITHREDUCED
PHYSICAL,SENSORIALORMENTALCAPACITIES,ORTHOSEWITHOUTTHENECESSARY
KNOWLEDGEANDEXPERIENCE.SUCHPERSONSMAYONLYUSETHEAPPLIANCEUNDER
THESUPERVISIONOFAPERSONRESPONSIBLEFORTHEIRSAFETY.