socomec COUNTIS E33 User Manual

socomec COUNTIS E33
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
A
B
D
C
COUNTIS E33
Hár
omfázisú, közvetlen bekötésű, aktív mérő 100A
J
BUS/MODBUS kommunikációval
Használati útmutató
Operating instructions - Bedienungsanleitung
Istruzioni per l’uso - Gebruiksaanwijzing
Instrucciones de servicio - Manual de instruções
GB
D I NL E P
H
Question and Answer IconNeed help?

Do you have a question about the socomec COUNTIS E33 and is the answer not in the manual?

socomec COUNTIS E33 Specifications

General IconGeneral
Brandsocomec
ModelCOUNTIS E33
CategoryMeasuring Instruments
LanguageEnglish

Summary

Personnel Safety and Device Operation

Risk of Electrocution, Burns, or Explosion

Precautions to prevent electric shock, burns, or explosion.

Risk of Device Damage

Checks to ensure correct voltage, frequency, and current.

Preliminary Operations and Checks

Safety and Package Inspection

Essential to read instructions before first use. Check package contents.

Receipt Confirmation

Check packaging, product, part number, and contents upon receipt.

Introduction to the COUNTIS E33 Meter

Meter Overview and Features

Describes the meter's capabilities, connection, and display.

Communication Interface and Functionalities

RS485 interface, JBUS/MODBUS protocol, and key meter functions.

Meter Components Identification

Identifies display, buttons, and LEDs on the meter.

JBUS/MODBUS Communication Setup

Communication Recommendations and Requirements

Advice on cable types, termination resistors, and protocol modes.

Installation Guidelines

Mounting and Connection Tools

Mounting on 35mm rail and required screwdriver types.

Electrical Connection Types

Three-Phase Supply and Wiring

Ensures meter accuracy by connecting all three phases; provides wiring diagrams.

Single Phase Supply and Wiring

Single-Phase Connection Diagram

Illustrates the single-phase connection with neutral.

Connection Test Procedure

Phase Connection Error Detection

Function to detect phase connection errors for accurate readings.

Test Setup, Execution, and Interpretation

Conditions for testing, how to run it, and interpreting results/errors.

Programming Modes and Configuration

Manual vs. Auto Configuration

Manual setting of parameters vs. automatic configuration.

Navigating Programming Menus

Entering and Selecting Programming Modes

Accessing programming mode and selecting Manual/Auto.

Menu Navigation Process

Procedure to move to the next menu item.

Manual Programming: Address and Speed Settings

Setting Communication Address

Setting the communication address for the device.

Setting Communication Speed

Setting the communication speed (baud rate).

Manual Programming: Parity and Stop Bit Settings

Setting Communication Parity

Setting the communication parity (odd/even/none).

Setting Communication Stop Bit

Setting the stop bit for communication (1 or 2).

Exiting Programming Mode

Automatic Exit and Configuration Loss

Automatic exit after inactivity; configuration is not saved.

Automatic Programming: Address Setting

Setting Address in Auto Mode

Setting the communication address when in automatic mode.

Operation: Display Information Overview

Meter Reading Displays

Shows partial meter, energy production/consumption, error, and tariff displays.

Parameter and Phase Indicators

Displays various parameters, units, and phase status.

Energy Meter Readings: Total Consumption

Total Energy by Tariff (T1-T4)

Displays total energy consumption for each tariff (T1-T4).

Overall Total Energy Consumption

Displays the sum of all tariff energy consumptions.

Energy Meter Readings: Partial Consumption

Partial Energy by Tariff (T1-T4)

Displays partial energy consumption for each tariff (T1-T4).

Overall Total Partial Energy Consumption

Displays the sum of all partial tariff energy consumptions.

Energy Production and Power Measurement

Total and Partial Energy Produced

Displays total and partial amounts of energy generated.

Instantaneous Power Display

Shows the current power consumption with direction.

Resetting Partial Meters

Procedure to Reset All Partial Meters

Resets all partial meters to zero by pressing the reset button.

Troubleshooting Common Issues

Device Power and Communication Errors

Steps for power issues, communication malfunctions, and error messages.

Phase Indicator Issues

Steps to resolve issues with phase presence indicators.

Technical Characteristics: System and Supply

System Connection and Frequency

Specifies supply types, number of wires, and operating frequency.

Consumption, Current, and Voltage Ratings

Details power supply, consumption, and current/voltage ratings.

Powers, Energy, Accuracy, and Tariffs

Covers powers, energy metering, accuracy class, and tariff management.

Display Specifications

Details display type, refresh time, and backlight.

Technical Specifications: Communication, Climate, and Case

Communication, Backup, and Climate Data

Details communication interface, protocol, backup, and environmental data.

Case Dimensions and Mounting

Specifies housing dimensions, mounting, and terminal capacities.

Options and Recycling Compliance

Covers optional features and product recycling compliance.