BTS E5~20-DS5 user manualV1.1
Copyright © Shenzhen SOFARSOLAR Co., Ltd
Figure. 4-9 Installation diagram of the protection ground cable
4.3.3 DC power cable installation
Procedure:
1) Select proper cable types and specifications based on Table 4-1.
Remove cable connectors from positive and negative
connectors. (It is suggested to use different colors to distinguish
positive and negative poles).
2) Use a wire stripper to strip off the insulation layer of the positive
and negative cables to a proper length. For details, see the
peeling length diagram.4-10.
3) Insert the positive and negative cables with the insulation layer
removed into the positive and negative metal terminals, and use
crimping pliers to press the cable to the metal core of the
terminal. Ensure that the cable is firmly crimped with the metal
core.
4) The crimped positive and negative cables pass through the