HYD 3000 ... 6000-EP User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd
- 48 -
4.Logic Interface
OK
Enable
OK
Disable
OK
5. Factory Reset
5.Factory Reset
OK
1.Clear Energy Data
OK
2.Clear Events
OK
Clean the inverter of the total power generation.
1.Clear Energy Data
OK
Please confirm!
Cancel
OK
Clear
OK
Clean up the historical events recorded in the inverter.
2..Clear Events
OK
Please confirm!
Cancel
OK
Clear
OK
6.
Parallel setting
Please refer to <4.7.3 Link Port 0&1-Cascade communication interface> for
the connection method of the parallel system.
6.Parallel setting
OK
1.Parallel Control
2.Parallel Primary-Replica
3.Parallel Address
4.Save
1Parallel Control: Enable or disable parallel functions. Both the master and
the slave must enable this function.
2Parallel Primary-Replica: Set up the Primary and Replica.Select one
inverter as the Primary and set the others to Replica.
3Parallel Address: Set the parallel address.Each inverter needs to set a
parallel address, and the parallel address in a parallel system cannot be repeated.
NOTE:The parallel address is different from the communication address used for
monitoring.
4Save: Save after the setup is complete.
7. Bluetooth Reset
7.Bluetooth Reset
OK
Please confirm!
OK
Success
8. CT Calibration
To calibrate the direction and phase of the CT, the battery should be charged
or discharged when using this function.
8.CT Calibration
OK
Start CT Calibration
Calibrating
Sucess/Fault
Check if the battery is charging or discharging when calibration fails