HYD 5-20KTL-3PH User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd。
Module 2 temperature
protection
Module 3 temperature
protection
Unbalanced bus voltage
RMS
Internal faults of inverter, switch OFF
inverter, wait for 5 minutes, then switch ON
inverter. Check whether the problem is
solved.
If no, please contact technical support.
The transient value of
bus voltage is
unbalanced
Busbar undervoltage
during grid-connection
Check whether the PV series voltage (Voc)
is higher than the maximum input voltage
of the inverter. If so, adjust the number of
PV modules in series and reduce the PV
series voltage to fit the input voltage range
of the inverter. After correction, the inverter
will automatically return to its normal state.
Check whether the battery overvoltage
setting is inconsistent with the battery
specification.
LLC BUS overvoltage
protection
Internal faults of inverter, switch OFF
inverter, wait for 5 minutes, then switch ON
inverter. Check whether the problem is
solved.
If no, please contact technical support.
Inverter bus voltage
RMS software
overvoltage
Inverter bus voltage
instantaneous value
software overvoltage