53
ID029
ConsistentGF
CI
Leakage current
consistency error
ID030
ConsistentVg
rid
Grid voltage
consistency error
ID031
ConsistentDC
I
DCI consistency
error
ID033
SpiCommFau
lt(DC)
SPI communication
error (DC)
ID034
SpiCommFau
lt(AC)
SPI communication
error (AC)
ID035
SChip_Fault
Chip error (DC)
ID036
MChip_Fault
Chip error (AC)
ID037
HwAuxPowe
rFault
Auxiliary power
error
ID041
RelayFail
Relay detection
failure
Internal faults of inverter, switch OFF inverter,
wait for 5 minutes, then switch ON inverter.
Check whether the problem is solved.
If not, please contact SOFARSOLAR technical
support.
ID042
IsoFault
Low insulation
impedance
Check the insulation resistance between the
photovoltaic array and ground (ground), if there is
a short circuit, the fault should be repaired in
time. If not solved, please contact
SOFARSOLAR technical support.
ID043
PEConnectFa
ult
Ground fault
Check ac output PE wire for grounding. If not
solved, please contact SOFARSOLAR technical
support.
ID044
PvConfigErro
r
Error setting input
mode
Check the input mode (parallel/independent
mode) Settings for the inverter. If not solved,
please contact SOFARSOLAR technical support.
ID045
CDTisconnec
t
CT Fault
Please check the wiring of input, output and
communication according to the user's manual. If
the use method is not ruled out, please contact
SOFARSOLAR technical support..
ID046
ReversalCon
nection
Input reverse
connection error
ID047
ParallelFault
Paralle lFault
ID048
SNTypeFault
SN doesn’t match
Type
It is internal fault of inverter.
ID049
Reserved
Reserved
ID050
TempErrHeat
Sink1
Radiator 1
temperature
protection
Ensure the installation position and installation
method meet the requirements of this user
manual. Check whether the ambient temperature
of the installation position exceeds the upper
limit. If yes, improve ventilation to decrease the
temperature. Check whether the inverter has dust
and dust, whether there are foreign matters
ID051
Reserved
Reserved
ID052
Reserved
Reserved
ID053
Reserved
Reserved
ID054
Reserved
Reserved