SE4K SE5K SE7K SE8K SE9K SE10K SE12.5K Unit
Protective class Class I
Utility monitoring,
islanding protection,
configurable Power
Factor, country
configurable
thresholds
Yes
Overvoltage category III
Input
Maximum DC power
(Module STC)
5400 6750 9450 10800 12150 13500 16850 W
Transformer-less,
ungrounded
Yes
Maximum input
voltage
900 Vdc
Nominal DC input
voltage
750 Vdc
Maximum input
current
7 8.5 12 13.5 15 16.5 21 Adc
Maximum back-feed
current
0 Adc
Reverse-polarity
protection
Yes
Ground-fault
isolation detection
700kΩ Sensitivity
Overvoltage category II
Maximum inverter
efficiency
98 %
European weighted
efficiency
97.3 97.3 97.3 97.5 97.5 97.6 97.7 %
Night-time power
consumption
< 2.5 W
-Three Phase System Installation Guide MAN-01-00057-4.1
106Technical Specifications - Three Phase Inverters (Europe &APAC)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge SE4000 and is the answer not in the manual?

SolarEdge SE4000 Specifications

General IconGeneral
ModelSE4000
ManufacturerSolarEdge
Rated AC Power4000 W
CEC Weighted Efficiency97.5%
Number of MPP Trackers1
Protection RatingIP65
CoolingNatural Convection
Warranty12 years
AC Output Power4000 W
AC Voltage220 / 230 / 240 Vac
Max. DC Input Power5400 W
Operating Temperature Range-25°C to 60°C