Communication Connectors
Two communication glands are used for connection of the various communication
options. Each gland has three openings. The table below describes the functionality of
each opening. Unused openings should remain sealed.
Gland# Opening Functionality Cable size (diameter)
1 (PG16)
One small External antenna cable 2-4 mm
Two large
Ethernet connection
(CAT5/6), Cellular, ZigBee,
or Wi-Fi
4.5-7 mm
2 (PG13.5) All three RS485, power reduction 2.5-5 mm
Figure 19: Communication Glands
The communication board has a standard RJ45 terminal block for Ethernet connection,
and a 9-pin terminal block for RS485 connection, as shown below:
Figure 20: Internal connectors
Chapter 7: Setting Up Communication 69
Three Phase System Installation Guide MAN-01-00057-4.1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge SE5000 and is the answer not in the manual?

SolarEdge SE5000 Specifications

General IconGeneral
ModelSE5000
ManufacturerSolarEdge
CategoryInverter
AC Output Power5000 W
Efficiency98.3%
CoolingNatural convection
Protection RatingIP65
Rated AC Power5000 W
Max. AC Power5000 VA
Maximum Input Voltage480 V
Number of MPP Trackers1
Max. Input DC Voltage480 V
Operating Temperature Range-25°C to 60°C
AC Voltage230 V