SolarMax S series
2000S /3000S /4200S /6000S
Instruction manual

Table of Contents

Other manuals for SolarMax S series

Questions and Answers

  • B
    Brooke Thompson DDSAug 19, 2025
    What should I do if my SolarMax Inverter shows 'Vac too low or Vac too high'?
    • M
      Madison FowlerAug 19, 2025
      If your SolarMax Inverter displays 'Vac too low' or 'Vac too high', the cause may be that the mains voltage is too low or too high. Check the mains voltage to ensure it is within the appropriate range.
  • M
    Morgan CastilloAug 21, 2025
    Why is my SolarMax S series Inverter showing 'Overtemperature'?
    • M
      Melissa HoltAug 21, 2025
      If your SolarMax Inverter is showing an 'Overtemperature' warning, this could be due to several reasons. The ambient temperature might be too high, or there may be insufficient air circulation. Ensure air can circulate at the side of the cooling fans. If a fan is blocked, clean or replace it.
  • L
    Laura LoweryAug 23, 2025
    What does it mean if my SolarMax S series Inverter displays 'Insulation fault'?
    • H
      Holly WilliamsAug 23, 2025
      If your SolarMax Inverter is showing an 'Insulation fault', it could be due to earth leakage or an insulation fault on the DC side. Check the solar generator and DC cabling. It may also be due to phase and neutral conductors being interchanged; in that case, swap the phase and neutral conductors in the AC coupling connector.
  • D
    Dr. Dale FloresAug 26, 2025
    What to do if my SolarMax S series Inverter displays 'Vdc too high'?
    • M
      Michael ContrerasAug 27, 2025
      If your SolarMax Inverter displays 'Vdc too high', it indicates that the solar generator voltage exceeds the permissible value. Immediately disconnect the DC insulation switch and check the module configuration.
  • L
    Lauren YoderAug 27, 2025
    What to do if my SolarMax Inverter displays 'Ierr too high'?
    • J
      Jennifer MartinAug 28, 2025
      If your SolarMax Inverter displays 'Ierr too high', it means the fault current is too large. Check the solar generator and DC cabling. It may also indicate an earth leakage or insulation fault on the DC side, in which case you should ensure equipotential bonding between the inverter and module frame.
  • B
    Brett WatsonAug 30, 2025
    How to fix a SolarMax S series with no graphics display?
    • A
      amyrogersAug 30, 2025
      If your SolarMax Inverter has no graphics display, it could be due to several reasons: * The DC insulation switch may be switched off. If so, switch it on. * The irradiance may be too low. Wait until irradiance is high enough. * Strings may be interrupted. If so, rectify the interruption. * It could be an internal fault. If so, notify the SolarMax hotline.
  • J
    James WuSep 1, 2025
    Why is my SolarMax Inverter flashing and displaying 'Irradiance too low'?
    • D
      Desiree RiceSep 1, 2025
      If the graphics display on your SolarMax Inverter flashes periodically or shows a status message indicating 'Irradiance too low', it means that the irradiance is too low. Wait until the irradiance is high enough for normal operation.
  • J
    Jared ThomasSep 3, 2025
    What does it mean when the alarm LED on my SolarMax Inverter is flashing green/red?
    • E
      ebony79Sep 3, 2025
      If the alarm LED on your SolarMax Inverter is flashing green/red, it indicates a temperature limitation. The inverter output is reduced when the heat sink temperature reaches 75 °C.
  • D
    Daniel OwensSep 5, 2025
    What does it mean if my SolarMax S series Inverter displays 'Iac asymmetric'?
    • L
      laustinSep 5, 2025
      If your SolarMax Inverter displays 'Iac asymmetric', it indicates that the DC component of the mains current is too large. First switch off the AC side and then the DC side for 20 seconds, then switch it on again. For recurring faults, contact the SolarMax hotline.
  • J
    Jeffrey ZunigaSep 7, 2025
    What should I do if my SolarMax S series displays 'No mains, frequency too high or too low'?
    • J
      Joshua BestSep 8, 2025
      If your SolarMax Inverter displays 'No mains, frequency too high or too low', it could be due to a grid or mains voltage interruption. Check the AC connection. It could also be that the mains frequency is outside the tolerance; in that case, wait until the mains frequency is within tolerance.

Summary

1 About this instruction manual

1.1 Target group

Manual is for fitters and operators of PV plants.

1.2 Where to keep this manual

Ensures the manual is available to responsible personnel at all times.

1.3 Symbols used

Explains DANGER, CAUTION, and NOTE symbols for safe operation.

2 Safety instructions

2.1 Appropriate use

Defines the inverter's intended purpose: converting DC to AC for the public grid.

3 Description

3.1 Technical configuration SolarMax 2000 S;3000 S

Details the DC voltage conversion and IGBT bridge circuit for 2000S/3000S models.

3.2 Technical configuration SolarMax 4200 S and SolarMax 6000 S

Describes the configuration for 4200S/6000S, including MaxShare concept.

3.3 External operating elements and dimensions

Details the external controls and physical dimensions of the inverter unit.

4 Installation

4.1 Transport and storage

Covers guidelines for safe transport and storage conditions for the inverter.

4.2 Site selection and operating conditions

Provides specifications and instructions for choosing a suitable installation location.

4.3 Cooling system

Explains the cooling mechanism, including cast aluminium base and fan.

4.4 Lightning protection

Addresses requirements for lightning protection and suggests consulting a qualified person.

4.5 Scope of delivery

Lists the items included in the inverter package shipment.

4.6 Installation

Details the procedure for physically installing the inverter using provided or alternative mounting rails.

4.7 Electrical connection

4.7.1 Guidelines for electrical installation

Provides safety guidelines for qualified electricians performing electrical connections.

4.7.2 Overview of the electrical connections

Shows a diagram of available pluggable connections on the inverter.

4.7.3 Specifications of the built-in overvoltage protection

Details the integrated surge protectors at the input and output stages.

4.7.4 Earthing of the inverter

Explains the requirements for secure protective conductor connection for earthing.

4.7.5 External fault interrupter (RCD)

Describes the integrated AC/DC sensitive fault current sensor and external RCD selection.

4.7.6 Connecting the inverters to the mains

Details connecting conditions, recommended fuses, and line cross-sections.

4.7.7 Connecting the inverters to the PV plant

Provides connection conditions for multiple strings and DC input requirements.

4.7.8 Connecting status signalling contact (optional)

Explains the status signalling contact for remote monitoring and its functionality.

4.7.9 Connecting the cable for data communications

Details connection recommendations for RJ45 sockets for RS485 and Ethernet.

5 Commissioning

5.1 Inspections prior to commissioning

Lists checks to perform before starting up the inverter.

5.2 Commissioning

Describes the automatic initial setup procedure and requirements for commissioning.

6 Operation

6.1 How the DC isolating switch works

Explains the function of the DC isolating switch in disconnecting the inverter.

6.2 Switching on the inverter

Details the procedure for switching on the inverter and its expected reactions.

6.3 Switching off the inverter

Outlines the procedure for safely switching off the inverter and its status indications.

6.4 Operating the graphics display

Guides on navigating menus, displaying system status, and using the inverter's interface.

7 Data communication

7.1 Configuration of the data communication interfaces

Details settings for Ethernet interfaces like device address, IP, Netmask, and TCP Port.

8 Options

8.1 Accessory components

Lists available accessory components such as MaxMeteo, MaxCount, and MaxDisplay.

9 Operating status

9.1 Status messages and status LED

Explains inverter status messages and LED colors indicating operational states.

9.2 Booting

Describes the booting process and status messages like 'Irradiance too low'.

10 Troubleshooting

10.1 SolarMax Service Centre

Provides contact details and required information for technical support.

10.2 Diagnosis & corrective steps

Describes measures for remedying failures and troubleshooting issues.

14 Specifications

14.1 Specifications

Presents technical specifications for SM2000S, SM3000S, SM4200S, SM6000S models.

14.2 Efficiency curve

Displays the inverter efficiency across different output power levels.

14.3 Temperature-dependent output reduction (power derating)

Shows how ambient temperature affects the inverter's output power.

14.4 Country specific settings

Lists parameter settings that vary based on country and grid regulations.

SolarMax S series Specifications

General IconGeneral
TopologyTransformerless
CoolingNatural Convection
Protection classIP65
EfficiencyUp to 98%
Output Voltage230V
Frequency50 Hz / 60 Hz
Protection FeaturesOvervoltage, Short Circuit, Over Temperature
Operating Temperature-25°C to 60°C