A
April StewartAug 29, 2025
What to do if SolaX Power X1-Hybrid-6.0-LV shows '1.2 times overload'?
- NNicholas BallAug 29, 2025
If your SolaX Power Inverter displays '1.2 times overload', turn off any high-power load connected to the inverter.
What to do if SolaX Power X1-Hybrid-6.0-LV shows '1.2 times overload'?
If your SolaX Power Inverter displays '1.2 times overload', turn off any high-power load connected to the inverter.
What should I do if my SolaX Power Inverter displays 'Low soc of grid-connected battery'?
If your SolaX Power Inverter displays 'Low soc of grid-connected battery', stop discharging and start charging.
What to do if my SolaX Power X1-Hybrid-6.0-LV Inverter displays 'Battery type configuration error'?
If your SolaX Power Inverter displays 'Battery type configuration error', turn off the PV, battery, and power grid, restart the inverter, and confirm whether the battery type is correct.
What should I do if my SolaX Power X1-Hybrid-6.0-LV Inverter displays 'Battery recharge'?
If your SolaX Power Inverter displays 'Battery recharge', check the battery voltage and replenish the power in time.
What should I check if my SolaX Power X1-Hybrid-6.0-LV Inverter displays 'Battery floating charge'?
If your SolaX Power Inverter displays 'Battery floating charge', check battery voltage.
What should I do if my SolaX Power Inverter displays 'BST2 hardware overcurrent'?
If your SolaX Power Inverter displays 'BST2 hardware overcurrent', wait for a while to see if it returns to normal.
What should I do if my SolaX Power Inverter displays 'BuckBst startup failed'?
If your SolaX Power Inverter displays 'BuckBst startup failed', wait for a while to see if it returns to normal.
What to do if SolaX Power Inverter displays 'Frequency configuration mismatch'?
If your SolaX Power Inverter shows a 'Frequency configuration mismatch', check whether the frequency is within the correct range.
What should I check if my SolaX Power Inverter displays 'Battery voltage is too high'?
If your SolaX Power Inverter displays 'Battery voltage is too high', check whether the battery output voltage is within the normal range.
What to do if my SolaX Power Inverter displays 'PV connection configuration error'?
If your SolaX Power Inverter shows a 'PV connection configuration error', turn off the PV, battery, and power grid. Then, restart the inverter and confirm whether the PV connection is correct.
Brand | SolaX Power |
---|---|
Model | X1-Hybrid-6.0-LV |
Category | Inverter |
Language | English |