86
Decommissioning
10 Decommissioning
10.1 Dismantling the inverter
10.2 Packaging
10.3 Storage and Transportation
• Remove DC input line and AC output line of inverter.
• Wait for at least 5 minutes to power o.
• Remove all cable connections from the inverter.
• Remove the inverter from the bracket.
• Remove the bracket if necessary.
If the original package can not be found, you can also use the following re-
quirements of the carton packaging:
• Bearing capacity of more than 30kg.
• Easy to carry.
• Can completely seal the cover.
Load the inverter into the original package if possible.
If it is necessary to scrap the inverter or other related parts, be sure to send
the waste inverter and packaging materials to the designated location for re-
cycling by the relevant department.
10.4 Waste Disposal
Store the inverter in a dry, temperature -25°.C~ 65°C environment. Pay atten-
tion to less than four inverters on each stack board during storage and trans-
portation.
Item Check Notes Maintenance Inverval
Input and
output
cables
• Cables are securely connected.
• Cables are intact, and in particular,
the parts touching the metallic
surface are not scratched. Check
whether the sealing caps of idle DC
input terminals fall o.
• Check that the idle COMM and
USB ports are locked by waterproof
caps.
Every 6 months
Grounding
reliability
Check whether the grounding terminal
and ground cable are securely
connected and all terminals and ports
are properly sealed.
Every 6 months