EasyManua.ls Logo

SolaX Power X3-Hybrid-10.0-D-E User Manual

SolaX Power X3-Hybrid-10.0-D-E
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
No.288 Shizhu Road, Tonglu Economic Development Zone,
Tonglu City, Zhejiang Province, China.
Tel: +86 0571-56260011
E-mail: info@solaxpower.com
X3-Hybrid
User Manual
5.0kw - 10.0kw
614.00364.01
Copyright Declaration
SolaX Power Network Technology(Zhe jiang) Co., Ltd.
The copyright of this manual belongs to SolaX Power Network Technology(Zhe jiang) Co.,
Ltd.. Any corporation or individual should not plagiarize, partially or fully copy (including
software,etc.), and no reproduction or distribution of it in any form or by any means. All rights
reserved. SolaX Power Network Technology (Zhe jiang) Co.,Ltd. . reserves the right of final
interpretation.
Question and Answer IconNeed help?

Do you have a question about the SolaX Power X3-Hybrid-10.0-D-E and is the answer not in the manual?

SolaX Power X3-Hybrid-10.0-D-E Specifications

General IconGeneral
ModelX3-Hybrid-10.0-D-E
TypeHybrid Inverter
Max. DC Voltage1000 V
Number of MPPTs2
Max. Input Current per MPPT13 A
Rated Grid Voltage230 V
AC Voltage Range180-280 V
Rated Grid Frequency50/60 Hz
THDi<3%
Protection DegreeIP65
TopologyTransformerless
Cooling MethodNatural convection
Max. DC Input Current per MPPT13 A
Rated AC Voltage230 V
AC Frequency50/60 Hz
Rated Power10 kW
Max. DC Power13 kW
Rated AC Power10 kW
Max. AC Power10000 W
Max. AC Apparent Power10 kVA
DC Injection Current<0.5% In
Battery Voltage Range40 V - 58 V
Max. Charging Power10 kW
Max. Discharging Power10 kW
CommunicationRS485
Operating Temperature Range-25°C to +60°C
Max. DC Input Power13 kW

Summary

Safety

Important Safety Instructions

Crucial safety guidelines for operating the inverter, covering high voltage, burns, and electric shock.

Technical Data

Installation

Electrical Connection

PV and Grid Connections

Guides for connecting PV modules and the public grid, including safety and technical details.

Battery, Earth, and Meter Connections

Procedures for connecting the battery, grounding, and external meters.

Firmware Upgrading

Setting

Configuration Parameters

Detailed settings for safety, power factor, grid interaction, and various inverter functions.

Battery, EPS, and System Settings

Configuration for battery management, EPS operation, system resets, metering, and passwords.

Troubleshooting

Trouble Shooting Guide

Provides guidance and solutions for common inverter faults and error messages.

Routine Maintenance

Related product manuals