Operation MethodOperation Method
I) Reset Energy
The user can clear the power energy by this function.
j) Reset Meter
The user can clear the meter energy by this function. Press “Up or “Down button
to select and long press “Down to confirm. (The user can select Yes” to reset
meter if the user purchases SolaX meter)
k) Reset Errorlog
The user can clear the errorlogs by this function. Press “Up or “Down button to
select and long press “Down to confirm.
Mode Select
>YES/NO<
Reset Energy
Reset
>YES/NO<
Reset Meter
Reset
>YES/NO<
Reset Errorlog
l) Reset WiFi
The user can restart the WiFi by this function.
Reset
>YES/N O<
Reset WiFi
44
45
m) Machine Type
The user can check the Machine Type by this function.
15.0-T
Machine Type
p) Dry Contact
The user can use the Dry Contact to connect heat pump by this function.
There are three functions(Disable/Manual/Smart Save) which can be
selected for Load Management. Disable means the heat pump is off. When
Manual is selected the user can control the external relay to remain close
or open manually. Smart Save” mode can set the values of the heat pump’s
on/off time and conditions, operating modes.
If the user uses the inverter dry contacts to control heat pump through
Adapter box, please refer to the Adapter Box Quick Installation Guide to set
the parameters here.
>Load Management<
Dry Contact
Load Management
Disable/Manual/Smart Save
Enter
Back
n) PV Connection
The user can select the PV connection type by this function.
Mode Select
Mode Select
> Multi/Comm <
o) Nline Control
The user can enable or disable the Nline Control by this function.
Mode Select
> Enable/Disable<
PV Connecon
Nline Control
Machine Type
Load Management

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solax X3-MIC G2 Series and is the answer not in the manual?

Solax X3-MIC G2 Series Specifications

General IconGeneral
Max. DC Voltage1100V
Number of MPPTs2
THDi<3%
DC Connection TypeMC4
Number of MPP Trackers2
CommunicationWiFi, Ethernet
Rated AC Voltage230V
AC Connection TypePlug
Operating Temperature Range-25°C to +60°C
CoolingFan
Cooling MethodFan
ModelX3-MIC G2 Series

Related product manuals