4. Technical Data
4.1 DC Input
6000
1000
640
120-980
130-800
16/16
20/20
150
2
1/1
8000
1000
640
120-980
170-800
16/16
20/20
150
2
1/1
12000
1000
640
120-980
260-800
16/16
20/20
150
2
1/1
16000
1000
640
120-980
315-800
16/16
20/20
150
2
1/1
20000
1000
640
120-980
395-800
16/16
20/20
150
2
1/1
4.2 AC Output
Max. AC output apparent power [VA]
Nominal AC voltage [V]
Nominal grid frequency [Hz]
Nominal AC output current [A]
Max. AC output current [A]
Inrush current [A]
THDi, rated power [%]
Displacement power factor
Feed-in phase
3000
3300
4.6/4.4
4.8
4000
4400
6.1/5.8
6.4
5000
5500
7.6/7.3
8.0
6000
6600
9.1/8.7
9.6
12 13
Introduction Technical Data
X3-MIC-3K-G2 X3-MIC-4K-G2 X3-MIC-6K-G2 X3-MIC-8K-G2
Model
Model
30000
1000
640
120-980
395-800
32/16
40/20
150
2
2/1
X3-MIC-12K-G2
10000
11000
15.2/14.5
16.0
27
<3%
0.8 leading ~ 0.8 lagging
Three-phase
24000
1000
640
120-980
315-800
32/16
40/20
150
2
2/1
X3-MIC-10K-G2
8000
8800
12.2/11.6
12.8
3~/N/PE, 220/380, 230/400
50/60 (±5)
X3-MIC-15K-G2
12000
13200
18.2/17.4
19.1
15000
15000
22.7/21.8
22.7
Standard
Object
A DC Switch
PV1 Connector
AC Connector
B
C
D
E
F
Description
USB for Upgrade
PV2 Connector
Object
PV1 Connector
RS485
B
D
F
Description
DONGLE
X3-MIC-5K-G2
10000
1000
640
120-980
210-800
16/16
20/20
150
2
1/1
X3-MIC-3K-G2 X3-MIC-4K-G2 X3-MIC-6K-G2 X3-MIC-8K-G2 X3-MIC-12K-G2X3-MIC-10K-G2
X3-MIC-15K-G2
X3-MIC-5K-G2
342 mm
434 mm
156 mm
X3-MIC G2 Size(3 kW, 4 kW, 5 kW, 6 kW): 342 mm*434 mm*144.5 mm
X3-MIC G2 Size(8 kW, 10 kW, 12 kW, 15 kW ): 342 mm*434 mm*156 mm
144. 5 mm
Nominal AC output
apparent power [VA]
DC disconnection switch
Max. short circuit current
(input A/input B) [A]
Max. input current
(input A/input B) [A]
MPPT voltage range@ full load [V]
MPPT voltage range [V]
Nominal input voltage [V]
Max. PV input voltage [V]
Max. PV array input power [W]
Startup voltage [V]
No. of MPPT
Strings per MPPT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solax X3-MIC G2 Series and is the answer not in the manual?

Solax X3-MIC G2 Series Specifications

General IconGeneral
Max. DC Voltage1100V
Number of MPPTs2
THDi<3%
DC Connection TypeMC4
Number of MPP Trackers2
CommunicationWiFi, Ethernet
Rated AC Voltage230V
AC Connection TypePlug
Operating Temperature Range-25°C to +60°C
CoolingFan
Cooling MethodFan
ModelX3-MIC G2 Series

Related product manuals