V4.2/6 Software Update
Page 5
INSTALLATION ON A REDUNDANT BLACKROCK SYSTEM
I
nstallation of software and support files on a redundant Blackrock system must be performed on one processor at a time
w
ith the other processor powered down. Do not attempt this process with both units running!
1. Check the contents of the Software Upgrade Kit against the packing list; if there are any omissions, please contact your
local SSL office before proceeding further.
Archiving the System Disk
2. As with all software installations, we strongly advise you to generate a ‘mirror’ copy of the C100 HDS System Disk
before proceeding. Open the SSH client on the networked computer and login to the C100 HDS system
(ref. Assumption A4.). Once you are logged in (as user
sbc
’), type:
backup_system_disk <CR>
This will create a time and date stamped backup file in the
system_backup
folder.
The backup process copies the entire C100 HDS System Disk and so will take a considerable time (~5min) to complete.
It is of course also recommended that any backups created are stored off-line elsewhere. This must be done separately
for both Blackrock processors but this can be done on both processors simultaneously.
3. To ensure that sufficient space is still available to contain the upgrade, on each system type:
df -h /home <CR>
Check that the percentage used is less than about 90%. If it
is higher, consider removing any old backups from the
system_backup
folder.
Installing the Support Software
4. Ensure that the slave Blackrock processor has been powered down. Proceed through the following steps on the master
processor first.
5. Place the C100 HDS Software Disk in the DVD drive in the networked computer and open a window that displays
the contents of the DVD do not place the software disk in the DVD drive on the Blackrock processor!
6. Locate the
updates
folder within the folders exported by the C100 HDS system (ref. Assumption A5.).
7. On the DVD, open the
C100_V4_2_6 Updates
folder and drag the following three
.rpm
files from the DVD into the
updates
folder:
kernel
SBC kernel and associated modules
ssl_console_files
Blackrock system software and files
ssl_host_tools
SBC support files and applications
8. Once the
.rpm
files have been copied, return to the SSH client and type:
install_updates <CR>
. This will unwrap and install each of the
.rpm
archives. Follow
the on-screen instructions to install them. Ignore any error
messages printed to the terminal during this time.

Other manuals for Solid State Logic C100 HDS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solid State Logic C100 HDS and is the answer not in the manual?

Solid State Logic C100 HDS Specifications

Power IconPower
console power100-240 V AC
power consumption300-700 W
DSP and Audio Processing IconDSP and Audio Processing
maximum input channels256
second input path channels512
utility busses24 mono
aux busses24 mono
dedicated ASG buses16
dedicated PGM buses12
delay modules64 modules, 5.4 seconds each
Weight and Dimensions IconWeight and Dimensions
max height100.6 cm
weight (40 fader)190 kg
height adjustment0 to +1 cm
width (40 fader, flat end trim)143.1 cm
max depth92.6 cm