Fill in the value in “Advanced Settings”.
Main circuit breaker current limit: Please fill in the value shown on the nameplate of the
breaker installed at the feed-in point. The actual executed current is the preset value minus
10A, thus prevent the situation of main breaker from tripping frequently due to overload.
*Please note that if set value is greater, the breaker will trip due to over-current, on the con-
tra, EV charge may not work normally, thus please ll in the value strictly obedient to the
value shown on the nameplate of the breaker.
Batte Discharge Cuto SOC: To prevent over-discharging of batte, when SOC reaches
this value, the batte will stop discharging to supply electric vehicle.
Maximum grid charging power: The maximum power allowed taken from the grid to charge
electric vehicle under green mode.