User Manual
ECA-B Series
Troubleshooting and Maintenance
6
※ 6.1Troubleshooting
When a fault or a protection occurs, the corresponding error message will be shown on
Solinteg cloud platform. The fault and protection are listed as below:
ErrorMessage Description Solution
Emergency button
has been pressed
Emergency button has been
pressed
Please remove the connector out of the po of vehicle
or the charging station and rotate the emergency but-
ton clockwise to reset it. If LED light indicator changes
to green or blue, the fault has been recovered; other-
wise, please contact technical suppo to check emer-
gency button.
Grounding Fault
EV charger station has not
been properly grounded.
Please contact technical support to check how the
grounding is going based on the measured voltage
between N line and PE line:
Proper grounding:[0,40]V
Improper grounding:[40,90]V
Not grounded:[90,130]V
Improper grounding+ reverse connection between L
line and N line:[130,180]V
Reverse connection between L line and Nline:[180,220]V
Over Temperature
1.Ambient temperature is
too high.
2. Sho circuit occurs.
1.Please provide shelter for EV charger station to avoid
direct sunlight.
2.Please make EV charger station away from the heat
source.
3.Please ensure ambient temperature lower than 40℃.
4.When ambient temperature is lower than 40℃, please
resta EV charger and check if the issue has been re-
covered after 1 min. If the issue still exists, please con-
tact technical suppo.
CP Error
1. Damaged charger cable
2. Issue caused by the vehi-
cle
Please contact technical suppo to check if there is any
destruction of insulation on charger cable or charging
with another vehicle to check if this issue still exists.