EasyManua.ls Logo

SOLIS S5-GR3P20K - Connect PV side of inverter

SOLIS S5-GR3P20K
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.0~6.0
4.012AWG
12~10AWG
.17..16.
5. Installation5. Installation
Before connecting inverter, please make sure the PV array open circuit
voltage is within the limit of the inverter.
Before connection, please make sure the polarity of the output voltage of
PV array matches theDC+andDC-symbols.
Figure 5.11 DC+ Connector Figure 5.12 DC- Connector
Please use approved DC cable for PV system.
Cable type
Cross sectionmm²
Range
Industry generic PV cable
model:PV1-F
Recommended value
The steps to assemble the DC connectors are listed as follows:
1. Strip off the DC wire for about 7mm, Disassemble the connector cap nut. (see Figure 5.13)
3. Crimp the contact pin to the wire using a proper wire crimper. (see Figure 5.15)
2. Insert the wire into the connector cap nut and contact pin. (see Figure 5.14)
4. Insert metal connector into top of connector, and tighten nut with torque 2.5-3 Nm
(see figure 5.16).
5. Measure PV voltage of DC input with multimeter, verify DC input cable polar
(see figure 5.17), and ensure each string of PV voltage in range of inverter operation.
Connect DC connector with inverter until hearing a slight clicking sound indicates
connection succeed. (see figure 5.18)
5.3.2 Connect PV side of inverter
+
-
Figure 5.13 Disassemble the Connector Cap nut
Figure 5.14 Insert the Wire into the
Connector Cap nut and contact pin
Figure 5.15 Crimp the contact pin to the wire Figure 5.16 Connector with Cap nut Screwed on
Figure 5.17 Multimeter measurement
Figure 5.18 Connect the DC
Connectors to the Inverter
Crimping plier
Caution:
If DC inputs are accidently reversely connected or inverter is faulty or not
working properly, it is NOT allowed to turn off the DC switch. Otherwise it may
cause DC arc and damage the inverter or even lead to a fire disaster.
The correct actions are:
*Use a clip-on ammeter to measure the DC string current.
*If it is above 0.5A, please wait for the solar irradiance reduces until the
current decreases to below 0.5A.
*Only after the current is below 0.5A, you are allowed to turn off the DC
switches and disconnect the PV strings.
* In order to completely eliminate the possibility of failure, please disconnect
the PV strings after turning off the DC switch to aviod secondary failures due
to continuous PV energy on the next day.
Please note that any damages due to wrong operations are not covered in
the device warranty.