EasyManua.ls Logo

SOLIS S5 User Manual

SOLIS S5
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation and Operation Manual
Solis S5 Phase InverterSingle
S5-GR1P(7-10)K
Ver1.1
Ginlong Technologies Co., Ltd.
Ginlong Technologies Co., Ltd.
No. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo,
Zhejiang, 315712, P.R.China.
Tel: +86 (0)574 6578 1806
Fax: +86 (0)574 6578 1606
If you encounter any problem on the inverter, please find out the inverter S/N
and contact us, we will try to respond to your question ASAP.
Please adhere to the actual products in case of any discrepancies in this user manual.

Questions and Answers:

SOLIS S5 Specifications

General IconGeneral
Number of MPPTs2
Rated Grid Frequency50/60Hz
THDi<3%
DC SwitchYes
Cooling MethodNatural Convection
Frequency50/60Hz
Operating Temperature Range-25°C to +60°C
Rated Grid Voltage230 V
MPPT Range200-1000 V
Output Voltage230 V

Summary

1. Introduction

1.1 Product Description

Details the Solis S5 Single Phase Inverters, their functions, and covered models.

1.2 Packaging

Lists all included parts when receiving the inverter, with illustrations.

2. Safety Instructions

2.1 Safety Symbols

Explains safety symbols used in the manual and their meanings.

2.2 General Safety Instructions

Provides general warnings and notes for safe inverter operation and connection.

2.3 Notice For Use

Outlines requirements for inverter installation and startup procedures.

2.4 Notice for Disposal

Provides guidance on environmentally responsible disposal of the product.

3. Overview

3.1 Front Panel Display

Describes the front panel layout, including power, operation, and alarm indicators.

3.2 LED Status Indicator Lights

Explains the meaning of different LED indicator lights and their status.

3.3 Keypad

Details the function of the four keys on the inverter's front panel.

3.4 LCD

Describes the information displayed on the inverter's two-line LCD screen.

4. Installation

4.3.1 Connect PV side of inverter

Steps for connecting the PV input to the inverter, including voltage limits.

4.3.2 AC output connections

Instructions for preparing and connecting AC output cables to the inverter terminals.

4.3.3 External ground connection

Guidance on connecting the external ground conductor to the inverter.

4.3.4 Max. over current protection device (OCPD)

Table defining OCPD ratings for Solis S5 Single Phase Inverters.

4.3.5 Inverter monitoring connection

Information on monitoring the inverter via Wi-Fi or GPRS communication devices.

4.3.6 Electrical connection diagram

Guidance for a simple installation of an inverter solar energy system.

4.3.7 Meter Connection(optional)

How to connect smart meters for Export Power Management or consumption monitoring.

4.3.8 CT connections(optional)

Diagrams for connecting a smart sensor for Export Power Management.

4.3.9 Logic interface connection

Instructions for connecting the logic interface via RJ45 for remote operation.

5. Start & Stop

5.1 Start the Inverter

Step-by-step procedure for safely starting up the inverter.

6. Operation

6.1 Main Menu

Overview of the four submenus available in the inverter's Main Menu.

6.2 Information

Accessing operational data and information from the inverter's main menu.

6.2.1 Lock screen

How to lock or unlock the inverter's LCD screen using the ESC and ENTER keys.

6.3 Settings

Accessing submenus for setting time and inverter address.

6.4 Advanced Info - Technicians Only

Accessing advanced information requires a password for qualified technicians.

6.4.1 Alarm Message

Displays the 100 latest alarm messages, scrollable via UP/DOWN keys.

6.4.2 Running Message

Provides running messages like internal temperature for maintenance.

6.4.8 Communication Data

Displays internal inverter data for service technicians.

6.4.9 Warning Message

Shows the 100 latest warning messages, scrollable via UP/DOWN keys.

6.5 Advanced Settings - Technicians Only

Accessing advanced settings menu, requiring password for technicians.

6.5.1 Selecting Standard

Used to select the grid's reference standard for different countries.

6.5.5 Reset Password

Sets a new password for the 'Advanced Info.' and 'Advanced information' menus.

6.5.6 Power control

Allows setting active and reactive power through power setting buttons.

6.5.7 Calibrate Energy

Allows revising total energy value to match previous readings.

6.5.8 Special Settings

Applicable for maintenance personnel; wrong operations may cause issues.

6.5.9 STD Mode settings

Settings for working mode, power rate limit, frequency derating, and initial settings.

6.5.10 Restore Settings

Resets all items in 'Special Settings' to their default values.

6.5.11 HMI Update

Function used for updating the inverter's LCD program.

6.5.12 Internal EPM Set

Functions related to smart meters or sensors for Export Power Management.

6.5.12.1 Mode Select

Selects the mode for EPM functions: EPM OFF, Meter in Load, Grid, Consumption Monitor, Current sensor.

6.5.12 Backflow Power

Defines the allowed export power into the grid, with positive/negative values.

6.5.12.3 Fail safe ON/OFF

Activates alarm and stops generation if CT/Meter connection is lost.

6.5.12.4 Meter Select

Defines the correct meter connected to the inverter, selecting 1PH or 3PH meter.

6.5.13 External EPM Set

Configures Solis external EPM device, options are 5G-EPM and Others-EPM.

6.5.17 Power Parameter

Calibrates inverter output energy; does not affect energy count with RGM.

6.6 AFCI function

Detects arc faults on the DC circuit and shuts down the inverter to prevent fires.

6.6.1 Enable the AFCI function

Enables the AFCI function through a specific path in the settings menu.

7. Maintenance

8. Troubleshooting

9. Specifications

10. Appendix

10.1 Grid standard selection guide

Guide to selecting the correct grid code for different countries and regions.