EasyManuals Logo

SOLIS S5 User Manual

SOLIS S5
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
6. Operation6. Operation
6.4.4 Daily Energy
The function is for checking the energy generation for selected day.
Figure 6.8 Select date for daily energy
YES=<ENT> NO=<ESC>
Select: 2020-01-01
Press DOWN key to move the cursor to day, month and year, press UP key to change the digit.
Press Enter after the date is fixed.
2020-01-01: 051.3kWh
2020-01-01: 061.5kWh
Figure 6.9 Daily energy
Press UP/DOWN key to move one date from another.
6.4.8 Communication Data
The screen shows the internal data of the Inverter (see Figure 6.14), which is for service
technicians only.
01-05: 01 25 E4 9D AA
06-10: C2 B5 E4 9D 55
Figure 6.14 Communication Data
6.4.6 Yearly Energy
YES=<ENT> NO=<ESC>
Select: 2020
Figure 6.12 Select year for yearly energy
2020: 0017513kWh
2019: 0165879kWh
Figure 6.13 Yearly energy
Press UP/DOWN key to move one date from another.
The function is for checking the energy generation for selected year.
Press DOWN key to move the cursor to day and year, press UP key to change the digit.
Press Enter after the date is fixed.
6.4.7 Daily record
The screen shows history of changing settings. Only for maintance personel.
6.4.3 Version
The screen shows the model version and the software version of the Inverter
Model: 08
Software Version: D20001
Figure 6.7 Model Version and Software Version
6.4.5 Monthly Energy
YES=<ENT> NO=<ESC>
Select: 2020-01
Figure 6.10 Select month for monthly energy
The function is for checking the energy generation for selected month.
Press DOWN key to move the cursor to day and month, press UP key to change the digit.
Press Enter after the date is fixed.
2020-02: 0510kWh
2020-01: 0610kWh
Figure 6.11 Month energy
Press UP/DOWN key to move one date from another.
The display shows the latest warn messages (see Figure 6.15). Screens can be scrolled 100
manually by pressing the UP/ DOWN keys. Press the ESC key to return to the previous menu.
Msg000:
T: 00-00 00:00 D: 0000
Figure 6.15 Warning Message
6.4.9 Warning Message
.31..30.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SOLIS S5 and is the answer not in the manual?

SOLIS S5 Specifications

General IconGeneral
Number of MPPTs2
Rated Grid Frequency50/60Hz
THDi<3%
DC SwitchYes
Cooling MethodNatural Convection
Frequency50/60Hz
Operating Temperature Range-25°C to +60°C
Rated Grid Voltage230 V
MPPT Range200-1000 V
Output Voltage230 V