9. Specifications
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated output current (Amps)
Power Factor (at rated output power)
Operating frequency range (Hertz)
Max.efficiency
EU efficiency
Model
Dimensions
Weight
50/60
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
THDi (at rated output power)
Startup voltage (Volts)
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
600
3/3
330
10000
10000
10000
45.5/43.5
100-500
120
Max. output current (Amps)
45.9
45-55 or 55-65
1/N/PE, 220/230
>0.99 (0.8 leading - 0.8 lagging)
Topology
Operating ambient temperature range
Transformerless
-25~+60
Grid connection standard
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
<30 dB(A)
Natural convection
Relative humidity
0-100%
Display
Communication connections
Warranty Terms
LCD, 2×20 Z.
5 Years (Extend to 20 Years)
Safety/EMC standard
IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
DC connection
AC connection
MC4 connector
Self consumption (night) 1 W
14+14+14
22+22+22
<3%
IP66
G98 or G99, VDE-AR-N 4105 / VDE V 0124,
EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019,
RD 1699 / RD 244 / UNE 206006 / UNE 206007-1,
CEI 0-21, C10/11, NRS 097-2-1,EIFS 2018.2,
IEC 62116, IEC 61727, IEC60068, IEC 61683,
EN 50530
RS485, Optional: Wi-Fi, GPRS, USB*
Optional USB* :only for the brazilian market
S5-GR1P10K
10.1 Grid standard selection guide
For different countries and regions, corresponding grid code needs to be selected in the
inverter LCD to meet the requirements of local network provider.
This instruction indicates how to change the grid code and what code should be selected in
different places.
This following list illustrates the grid standard options in the inverter which are subject to
change. It is for your reference only. If customer has any doubts or uncertainty, please
consult Solis service department for confirmation.
To set the correct grid code, please enter the following path:
Advanced Settings -> Password:0010 -> Select Standard
Detailed protection limits can be viewed when choosing the code.
Please select "Save&Send" to enforce the code.
NOTE:
Please check if the grid code setting comply with local requirement.
NO.
1
2
3
4
5
6
7
8
9
10
11
12
Code in LCD
VDE4015
EN50549 PO
EN50549 NL
EN50438 L
France
C10/11
NRS097
CEI0-21
G98
G99
Country/Region
Germany
Poland
Netherland
France
Belgium
South Africa
Italy
UK
UK
Comments
For German Low Voltage Grid.
For Polish Low Voltage Grid
For Dutch Low Voltage Grid
General EN50438 Requirement.
Possible to be used in Austria, Cyprus, Finland,
Czech Republic, Slovenia, etc.
For French Low Voltage Grid
For Belgian Low Voltage Grid
For South African Low Voltage Grid
For Italian Low Voltage Grid
For UK Low Voltage Grid <16A
For UK Low Voltage Grid >16A
-
-
EIFS- SW
Sweden For Swedish Low Voltage Grid
EN50549L
(EN50549-1)
General EN50549-1 requirement which meets
local requirements of most European countries
10. Appendix
.50. .51.
4000m
OT Terminal
98.0%
97.1%
18.5kg
333W*579H*253D (mm)