CAUTION:
Risk of electric shock from energy stored in capacitors of the Inverter.
Do not remove cover for 5 minutes after disconnecting all power sources
(service technician only). Warranty may be voided if the cover is removed
without unauthorized.
CAUTION:
The surface temperature of the inverter can exceed 75 (167F).
To avoid risk of burns, DO NOT touch the surface when inverter is operating.
The inverter must be installed out of reach of children.
CAUTION:
The PV array (Solar panels) supplies a DC voltage when they are exposed to
sunlight.
WARNING:
To reduce the risk of fire, over-current protective devices (OCPD) are
required for circuits connected to the Inverter.
The DC OCPD shall be installed per local requirements. All photovoltaic source
and output circuit conductors shall have disconnects that comply with the NEC
Article 690, Part II. All Solis S6 Single Phase Inverters feature an integrated
DC switch.
CAUTION:
Risk of electric shock. Do not remove cover. There is no user serviceable
parts inside. Refer servicing to qualified and accredited service technicians.
WARNING:
Do not touch any inner live parts until 5 minutes after disconnection from
the utility grid and the PV input.
2. Safety Instructions 2. Safety Instructions
2.3 Notice For Use
The inverter has been constructed according to the applicable safety and technical
guidelines. Use the inverter in installations that meet the following specifications only:
Permanent installation is required.
The electrical installation must meet all the applicable regulations and standards.
The inverter must be installed according to the instructions stated in this manual.
The inverter must be installed according to the correct technical specifications.
To startup the inverter, the Grid Supply Main Switch (AC) must be switched on, before
the solar panel's DC isolator shall be switched on. To stop the inverter, the Grid Supply
Main Switch (AC) must be switched off before the solar panel's DC isolator shall be
switched off.
2.4 Notice for Disposal
This product shall not be disposed of with household waste. They should
be segregated and brought to an appropriate collection point to enable
recycling and avoid potential impacts on the environment and human health.
Local rules in waste management shall be respected .
WARNING:
Electrical installations must be done in accordance with the local and national
electrical safety standards.
.6. .7.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SOLIS S5 and is the answer not in the manual?

SOLIS S5 Specifications

General IconGeneral
Number of MPPTs2
Rated Grid Frequency50/60Hz
THDi<3%
DC SwitchYes
Cooling MethodNatural Convection
Frequency50/60Hz
Operating Temperature Range-25°C to +60°C
Rated Grid Voltage230 V
MPPT Range200-1000 V