9. Specifications
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated output current (Amps)
Power Factor (at rated output power)
Operating frequency range (Hertz)
Max.efficiency
EU efficiency
Model
Dimensions
Weight
50/60
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
THDi (at rated output power)
Startup voltage (Volts)
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
600
14+14+14
22+22+22
3/3
98.0%
97.1%
18.5kg
330
7000
7700
7700
31.8/30.4
100-500
120
Max. output current (Amps)
33.7
45-55 or 55-65
<3%
1/N/PE, 220/230
>0.99 (0.8 leading - 0.8 lagging)
Topology
Operating ambient temperature range
Transformerless
-25~+60
Grid connection standard
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
IP66
<30 dB(A)
Natural convection
4000m
Relative humidity
0-100%
Display
Communication connections
Warranty Terms
LCD, 2×20 Z.
5 Years (Extend to 20 Years)
Safety/EMC standard
IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
DC connection
AC connection
MC4 connector
RS485, Optional: Wi-Fi, GPRS, USB*
Self consumption (night) 1 W
333W*579H*253D (mm)
G98 or G99, VDE-AR-N 4105 / VDE V 0124,
EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019,
RD 1699 / RD 244 / UNE 206006 / UNE 206007-1,
CEI 0-21, C10/11, NRS 097-2-1,EIFS 2018.2,
IEC 62116, IEC 61727, IEC60068, IEC 61683,
EN 50530
Optional USB* :only for the brazilian market
S5-GR1P7K
.47.
8. Troubleshooting
Screen OFF
with DC applied
Inverter internally damaged
1.Do not turn off the DC switches as it will
damage the inverter.
2.Please wait for the solar irradiance reduces
and confirm the string current is less than
0.5A with a clip-on ammeter and then turn
off the DC switches.
3.Please note that any damages due to wrong
operations are not covered in the device
warranty.
DCinj-FAULT
High DC injection current
1.Check AC and DC connection
2.Check inverter inside cable connection.
1.Restart inverter or contact installer.
1.Restart inverter or contact installer.
Alarm Message
Failure description
Solution
ILeak-PRO
01/02/03/04
Leakage current protection
RelayChk-FAIL
Relay check fail
Table 8.1 Fault message and description
NOTE:
If the inverter displays any alarm message as listed in Table 8.1; please
turn off the inverter (refer to Section 5.2 to stop your inverter) and wait
for 5 minutes before restarting it (refer to Section 5.1 to start your inverter).
If the failure persists, please contact your local distributor or the service
center.
Please keep ready with you the following information before contacting us.
1. Serial number of Solis Single Phase Inverter;
2. The distributor/dealer of Solis Single Phase Inverter (if available);
3. Installation date.
4. The description of problem (i.e. the alarm message displayed on the LCD and the status
of the LED status indicator lights. Other readings obtained from the Information submenu
(refer to Section 6.2) will also be helpful.);
5. The PV array configuration (e.g. number of panels, capacity of panels, number of strings
, etc.);
6. Your contact details.
AFCI self-detection
(model with AFCI
module)
AFCI module self-detect fault
1.Restart inverter or connect technician.
Arcing protection
(model with AFCI
module)
Detect arc in DC circuit
1. Check inverter connection whether arc
exists and restart inverter.
.46.
OT Terminal

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SOLIS S5 and is the answer not in the manual?

SOLIS S5 Specifications

General IconGeneral
Number of MPPTs2
Rated Grid Frequency50/60Hz
THDi<3%
DC SwitchYes
Cooling MethodNatural Convection
Frequency50/60Hz
Operating Temperature Range-25°C to +60°C
Rated Grid Voltage230 V
MPPT Range200-1000 V
Output Voltage230 V