9. Specifications
9. Specifications
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated output current (Amps)
Power Factor (at rated output power)
Operating frequency range (Hertz)
Max.efficiency
EU efficiency
Model
Dimensions
Weight
50/60
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
THDi (at rated output power)
Startup voltage (Volts)
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
600
3/3
330
8000
8800
8800
36.4/34.8
100-500
120
Max. output current (Amps)
36.6
1/N/PE, 220/230
>0.99 (0.8 leading - 0.8 lagging)
Topology
Operating ambient temperature range
Transformerless
-25℃~+60℃
Grid connection standard
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
<30 dB(A)
Natural convection
Relative humidity
0-100%
Display
Communication connections
Warranty Terms
LCD, 2×20 Z.
5 Years (Extend to 20 Years)
Safety/EMC standard
IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
DC connection
AC connection
MC4 connector
Self consumption (night) <1 W
14+14+14
22+22+22
G98 or G99, VDE-AR-N 4105 / VDE V 0124,
EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019,
RD 1699 / RD 244 / UNE 206006 / UNE 206007-1,
CEI 0-21, C10/11, NRS 097-2-1,EIFS 2018.2,
IEC 62116, IEC 61727, IEC60068, IEC 61683,
EN 50530
<3%
IP66
RS485, Optional: Wi-Fi, GPRS, USB*
Optional USB* :only for the brazilian market
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated output current (Amps)
Power Factor (at rated output power)
Operating frequency range (Hertz)
Max.efficiency
EU efficiency
Model
Dimensions
Weight
50/60
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
THDi (at rated output power)
Startup voltage (Volts)
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
600
3/3
330
9000
9900
9900
40.9/39.1
100-500
120
Max. output current (Amps)
41.3
45-55 or 55-65
1/N/PE, 220/230
>0.99 (0.8 leading - 0.8 lagging)
Topology
Operating ambient temperature range
Transformerless
-25℃~+60℃
Grid connection standard
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
<30 dB(A)
Natural convection
Relative humidity
0-100%
Display
Communication connections
Warranty Terms
LCD, 2×20 Z.
5 Years (Extend to 20 Years)
Safety/EMC standard
IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
DC connection
AC connection
MC4 connector
Self consumption (night) <1 W
14+14+14
22+22+22
<3%
IP66
G98 or G99, VDE-AR-N 4105 / VDE V 0124,
EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019,
RD 1699 / RD 244 / UNE 206006 / UNE 206007-1,
CEI 0-21, C10/11, NRS 097-2-1,EIFS 2018.2,
IEC 62116, IEC 61727, IEC60068, IEC 61683,
EN 50530
RS485, Optional: Wi-Fi, GPRS, USB*
Optional USB* :only for the brazilian market
S5-GR1P9KS5-GR1P8K
.48. .49.
4000m4000m
OT TerminalOT Terminal
98.0%
97.1%
18.5kg
333W*579H*253D (mm)
98.0%
97.1%
18.5kg
333W*579H*253D (mm)
45-55 or 55-65