9. Specifications
9. Specifications
.48. .49.
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated output current (Amps)
Power Factor (at rated output power)
Operating frequency range (Hertz)
Max.efficiency
EU efficiency
Model
Dimensions
Weight
310W*543H*160D (mm)
50/60
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
THDi (at rated output power)
Startup voltage (Volts)
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
600
2/2
97.3%
96.6%
11.2kg
330
3000
3300
3300
13.6/13
S6-GR1P3K
90...520
120
Max. output current (Amps)
15.7
45...55 or 55...65
<3%
1/N/PE, 220/230
>0.99 (0.8 leading - 0.8 lagging)
Topology
Operating ambient temperature range
Transformerless
-25℃.. .+60℃
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
<20 dBA
Natural convection
Relative humidity
0~100%
Self consumption (night)
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated output current (Amps)
Power Factor (at rated output power)
Operating frequency range (Hertz)
Max.efficiency
EU efficiency
Model
Dimensions
Weight
310W*543H*160D (mm)
50/60
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
THDi (at rated output power)
Startup voltage (Volts)
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
97.3%
96.6%
600
2/2
11.2kg
330
3600
4000
4000
16.0/15.7
S6-GR1P3.6K
90...520
120
Max. output current (Amps)
16.0
45...55 or 55...65
<3%
1/N/PE, 220/230
>0.99 (0.8 leading - 0.8 lagging)
Topology
Operating ambient temperature range
Transformerless
-25℃.. .+60℃
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
<20 dBA
Natural convection
Relative humidity
0~100%
Self consumption (night)
Grid connection standard
VDE-AR-N 4105 / VDE V 0124, EN 50549-1,
VDE 0126 / UTE C 15 / VFR:2019, G98 or G99,
RD 1699 / RD 244 / UNE 206006 / UNE 206007-1,
CEI 0-21, C10/11, NRS 097-2-1, TOR,
EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068,
IEC 61683, EN 50530, MEA, PEA
Display
Communication connections
Warranty Terms
LCD, 2×20 Z.
5 Years (Extend to 20 Years)
Safety/EMC standard
DC connection
AC connection
MC4 connector
Quick connection plug
Grid connection standard
VDE-AR-N 4105 / VDE V 0124, EN 50549-1,
VDE 0126 / UTE C 15 / VFR:2019, G98 or G99,
RD 1699 / RD 244 / UNE 206006 / UNE 206007-1,
CEI 0-21, C10/11, NRS 097-2-1, TOR,
EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068,
IEC 61683, EN 50530, MEA, PEA
Display
Communication connections
Warranty Terms
LCD, 2×20 Z.
5 Years (Extend to 20 Years)
Safety/EMC standard
DC connection
AC connection
MC4 connector
Quick connection plug
<1 W<1 W
IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-3IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-3
14+14
22+22
RS485, Optional: Wi-Fi, GPRS, USB*
14+14
22+22
RS485, Optional: Wi-Fi, GPRS, USB*
IP66IP66
Optional USB* :only for the brazilian marketOptional USB* :only for the brazilian market
4000m4000m