70
© 2013 Somfy SAS. All rights reserved. 06/2013
EN
6. COMMISSIONING
3URJUDPPLQJWKH¿UVW
Somfy local control
point
Only one motor should be powered at a time.
Switch on and follow procedure «a» or «b»
depending on the reaction of the blind:
D7KHEOLQGPRYHVEULHÀ\
The end limits are set and no
Somfy control point has been stored.
*RWRWKHVHFWLRQHQWLWOHG©3URJUDPPLQJWKH¿UVW
Somfy io local control point».
or
b) The blind does not move
Press the Up or Down buttons and follow
procedure «c» or «d» depending on the reaction of the
blind:
The guide only describes commissioning using a Situo mobile io VB type Somfy io local control point which
provides greater precision when tilting the slats.
For commissioning using any other io control point, refer to the corresponding guide.
6.1. Identifying setting steps already completed
c or d
5. WIRING
 Connect the motor and plate assembly
according to the information in the table
below:
1 2 3
Shared
(Black)
Neutral
(Blue)
Earth (Yellow/Green)
M M M
Shared
Neutral
Earth
Motor
M
Shared
Neutral
Earth
Motor
Black (2)
Blue (1)
Yellow/Green
Cut off the mains power supply.
This motor must not be connected to an isolation transformer.
Only the io plate ref: 1811130 may be connected to the J4 io motor.