8.5. Modifying the position of the horizontal slats
 Press the Up and Down buttons for 5 seconds on the control
point: The blindPRYHVEULHÀ\
 Press the “myand Down buttons on the control point: the
blindPRYHVEULHÀ\
 0RYHWKHVODWVWRZDUGVWKHKRUL]RQWDOSRVLWLRQE\EULHÀ\SUHVV-
ing the Up or Down button on the control point.
 7RFRQ¿UPWKHKRUL]RQWDOVODWSRVLWLRQSUHVVsimultaneously on
the “my” and Down buttons on the control point until the blind
moves.
If necessary, it possible to perform this setting in the factory
EHIRUHWKH¿QDOSDLULQJ
Before doing this setting, you must set the angular
travel.
9. TIPS AND RECOMMENDATIONS
This setting is only necessary when using a light sensor
DQG XVLQJ D  NLQHPDWLF EOLQG 7LOWLQJ WUDYHO VLQFH
WKHORZHUHQGOLPLWRI !VODWVQRWKRUL]RQWDOZKHQWKH
blind rises)
9.1. Questions on the J4 io?
Observations Possible causes Solutions
The blind does not
operate.
The wiring is incorrect. Check the wiring and modify it if necessary.
The motor is hot. Wait until the motor cools down.
The Somfy io control point battery
is low.
Check whether the battery is weak and
replace it if necessary.
The control point is not compatible.
Check for compatibility and replace the
control point if necessary.
The Somfy io control point used
has not been programmed into the
actuator.
Use a programmed control point or program
this control point.
The blind stops too
soon or too late.
The end limits have been incorrectly
set.
Readjust the end limits.
Despite the presence
of a sunlight sensor,
when the sunlight is
low the blind does
not tilt the slats to the
horizontal position.
The sensor is not paired/set.
Read the sensor manual to carry out the
pairing and appropriate settings
The sensor is paired/set. Readjust the angular travel.
The "my" position is cleared. Set the "my" position.