S201 AFM
3 - EMERGENCY PROCEDURES
3.3 - ENGINE FAILURES
27/06/2019
SONAIR-S2-D-MAN-006
Rev. : A
3.3.3 ENGINE FAILURE IN FLIGHT
Engine failure or engine stopped:
1. Turnkey position - check both ignition channels are on.
2. Throttle position - check position (power as required).
3. Fuel selector valve - change to opposite tank except if
already empty
4. Auxiliary fuel pump - on
5. Main fuel pump - check circuit breaker pushed
If engine did not restart
6. Start gliding descent at flaps UP, 65 KIAS
7. Refer to 3.3.4 EMERGENCY LANDING WITH ENGINE OFF
NOTE
In case of Main fuel pump filter clogging, engine may run
irregularly and shut down if Full Power is applied. In this
case, reduce power lever to 65%