CDU-541
CD-ROM
DRIVE
SCSI
INTERFACE
MANUAL
4.
Logical
Characteristics
The
logical
characteristics
of
the
controller
comply
with
ANSI
X3.131-1986
for
a
single-ended
asynchronous
implementation.
The
controller
supports
disconnect/reselect.
Several
additional
logical
characteristics
are
discussed
here
to
aid
in
understanding
the
operation
of
the
drive
and
controller.
4 .
1.
Condi
tions
TQis
section
describes
certain
conditions
as
they
relate
to
the
operation
of
the
drive
and
the
interface.
4.1.1.
Power-on
Condition
The power-on
condition
occurs
when
power
is
first
applied
to
the
unit.
The
controller
performs
power-on
diagnostics.
If
a caddy
is
inserted
the
drive
loads
the
caddy and
attempts
to
read
the
table
of
contents.
For
the
duration
of
the
power-on
condition
the
controller
will
return
BUSY
status.
If
a
failure
in
power-on
diagnostics
occurs
the
controller
will
return
CHECK
CONDITION
STATUS.
If
after
the
caddy
is
inserted
it
does
not
seat
properly,
or
the
drive
is
unable
to
focus,
or
the
drive
is
unable
to
achieve
spindle
lock-up
or
the
table
of
contents
is
not
recovered
the
controller
will
return
a
CHECK
CONDITION
STATUS.
4.1.2.
Reset
Condition
The
reset
condition
occurs
whenever
the
RST
signal
is
asserted,
or
a
BUS
DEVICE
RESET
message
is
received.
4.1.3.
Unit
Attention
Condition
The
unit
attention
condition
occurs
following
a power-on
condition,
a
reset
condition,
the
insertion
of
a caddy
with
the
successful
recovery
of
the
table
of
contents
or
the
receipt
of
a
MODE
SELECT
command
from
another
initiator.
The
unit
attention
condition
will
persist
for
each
initiator
until
that
initiator
issues
a
command
to
the
logical
unit
for
which
the
controller
returns
a
CHECK
CONDITION
status.
If
the
next
command
from
that
initiator
to
the
logical
unit
(following
the
CHECK
CONDITION
status)
is
REQUEST
SENSE,
then
the
UNIT
ATTENTION
sense
key
is
returned.
If
any
command
other
than
REQUEST
SENSE
is
received,
the
unit
attention
condition
is
lost.
If
more
than
one
unit
attention
condition
occurs
the
unit
attention
condition
with
the
highest
priority
will
be
reported.
The
priority
is
1) Power on /
reset
2)
Not
ready
to
ready
transi~~en
(medium change)
3)
MODE
SELECT
command
istnea-trom
another
initiator
If
an
INQUIRY
command
is
received
from an
initiator
with
a
pending
unit
attention
condition
the
controller
will
perform
th~
INQUIRY
command
and
will
not
clear
the
unit
attention
condition.
If
a
REQUEST
SENSE
command
is
received
from an
initiator
with
a
pending
unit
attention
condition
then
the
controller
will
discard
any
pending
sense
data,
report
UNIT
ATTENTION
sense
key,
and
clear
the
unit
attention
condition
for
4-1