CDU-541
CD-ROM
DRIVE
SCSI
INTERFACE
MANUAL
5
.2.27.
REQUEST
SENSE
Command
==============================================================================
Bitl
Byte
I
7
6
5
4
3
2 1
a
==============================================================================
o I
Operation
Code (03h) I
-----1-----------------------------------------------------------------------1
1 :
Logical
Unit
Number:
Reserved
I
-----1-----------------------------------------------------------------------1
2 :
Reserved
I
-----1-----------------------------------------------------------------------1
3 I
Reserved
I
-----\-----------------------------------------------------------------------1
4 :
Allocation
Length
I
-----1-----------------------------------------------------------------------1
5 I
Control
Byte
I
==============================================================================
The
REQUEST
SENSE
command
requests
that
the
controller
transfer
sense
data
to
the
initiator.
The
sense
data
will
be
valid
after
a
CHECK
CONDITION
status
has
been
returned
on
the
previous
command.
This
sense
data
will
be
preserved
by
the
controller
for
the
initiator
until
1)
it
is
retrieved
by a
REQUEST
SENSE
command from
that
initiator.
2)
the
receipt
of
~~other
command
for
the
same
logical
unit
from
that
initiator.
3)
a
reset
condition
occurs.
Note:
The
sense
data
will
be
cleared
upon
receipt
of
any
subsequent
command
for
the
same
logical
unit
from
the
initiator
that
was
returned
the
CHECK
CONDITION
status.
See
Section
4.1.3.
The
REQUEST
SENSE
command
will
return
the
CHECK
CONDITION
status
only
to
report
catastrophic
errors
for
the
REQUEST
SENSE
command.
Following
a
catastrophic
error
on a
REQUEST
SS~SE
command,
sense
data
may
be
invalid.
For
example:
1)
A
reserved
bit
is
set
the
command
descriptor
block.
2)
An
unrecovered
parity
error
occurs
on
the
bus.
3)
A
controller
malfunction
prevents
return
of
the
sense
data.
If
an
error
occurs
during
the
execution
of
the
REQUEST
SENSE
command,
but
it
is
not
catastrophic,
the
controller
will
return
the
sense
data
with
GOOD
status.
5-51