Chapter
 
19
 
Switcher
 
Setup
 
FC Output 1 and 2
4)
 
DME Monitor 1 and 2
2) 5)
 
1)
 
M/E output signals selected in the M/E Output Assign menu.
 
2) MVS-6520/6530/3000A only 
3)
 
Makes duplicate assignments if the signal that is assigned is the same
 
signal as one already assigned to one of Output 1 to xx. However, the
 
following signals are unavailable if already assigned to Output 1 to
 
xx. 
Out 1 to xx 
Multi Viewer 1 and 2 
FC Output 1 and 2 
DME Monitor 1 and 2 
4)
 
FC Output 1 and 2 can be assigned as a pair combination to Outputs
 
15 and 16 or Outputs 31 and 32. 
5)
 
MKS-6570 output signal. The output signal is selected in the
 
Engineering Setup >DME >Output >Monitor Output menu (7343.1)
 
(
1 
p. 364). In addition, the output signal can be displayed
 
graphically using [Monitor Out] in the DME >Input/Output 
>Graphic menu (4164) (
1 
p. 172).
 
3 
Select the output connector number and signal to be
 
assigned. 
For output connectors not to be assigned, press
 
[Inhibit]. 
4 
Press [Set] to confirm the assignment. 
 
Adjusting the Video Clip 
1 
Open the Engineering Setup >Switcher >Output 
>Video Clip menu (7333.2). 
2 
Select the output you want to set. 
3 
Adjust the following parameters. 
 
 
Luminance signal white clip value 
Luminance signal dark clip value 
Chrominance signal clip value 
To set the values to the default values, press [Default]. 
 
 
Making Vertical Blanking Interval
 
Adjustment and Through Mode
 
Settings 
This sets the number of scan lines from the reference
 
blanking position of field 1 for each format that should be
 
masked. 
1 
Open the Engineering Setup >Switcher >Output >V
 
Blank/Through menu (7333.3). 
2 
Select the output you want to set. 
3 
Press [V Blank Mask]. 
4 
Adjust the following parameter. 
 
 
Final value for vertical blanking 
interval
a)
 
a)
 
Depending on the signal format, the adjustment range varies as
 
follows. 
480i: 10 to 19 
576i: 6 to 22 
1080i/1080PsF: 7 to 20 
720P: 7 to 25 
5 
To enable through mode, press [Through Mode],
 
setting it to Enable. The following outputs can be
 
enabled. 
•
 
Aux 1 to 24 outputs 
•
 
Program outputs of the M/E and PGM/PST rows 
•
 
Clean outputs of the M/E and PGM/PST rows 
 
 
Making Safe Title Settings 
1 
Open the Engineering Setup >Switcher >Output >Safe
 
Title menu (7333.4). 
The status area shows the output connectors and the
 
assigned signals, with the box 1, box 2, cross, and grid
 
states. 
2 
Select the output you want to set. 
3 
To enable the safe title on/off setting made in the Misc
 
menu, press [Safe Title], turning it on. 
4 
Carry out one of the following operations. 
To display a box: Press [Box1] or [Box2], turning it
 
on. 
In this case, carry out the following steps 5 and 6. 
To display a cross: Press [Cross], turning it on. 
To display a grid: Press [Grid], turning it on. 
In this case, carry out the following steps 5 and 6. 
5 
If you selected [Box1] or [Box2] in step 4, adjust the
 
following parameters. 
 
 
a)
 
Adjustable for Box2 
If [Grid] is selected in step 4, in the <Grid Size> group,
 
select one of the following. 
80.00%: Sets the grid size to 80% of the screen frame. 
85.00%: Sets the grid size to 85% of the screen frame.