— 22 —
KV-21FA210
ADJUSTMENT ITEMS (5 OF 8)
DEVICE "RGB"
Item# OSD DETAIL
Range
(DEC)
Initial Data
1 AMUT RGB POWER ON MUTE 00-01 0
2 PMUT RGB MUTE(EXCEPT OSD) 00-01 1
3 VBLK 00-01 0
4 CORL R CUTOFF lower 00-255 200
5 CORH R CUTOFF upper 00-01 0
6 COGL G CUTOFF lower when Color Temp. is "Cool" and "Neutral" 00-255 200
7 COGH G CUTOFF upper when Color Temp. is "Cool" and "Neutral" 00-01 0
8 COBL B CUTOFF lower when Color Temp. is "Cool" and "Neutral" 00-255 200
9 COBH B CUTOFF upper when Color Temp. is "Cool" and "Neutral" 00-01 0
10 ABLS ABL SELECT (ON:00, OFF:01) 00-01 0
11 ACLS ACL ON (ON:00, OFF:01) 00-01 1
12 ALSP ACL SPEED 00-03 1
13 ALRS ACL RECOVER SPEED 00-15 2
14 ALAS ACL ATTACK SPEED 00-15 9
15 ABLG ABL GAIN 00-15 15
16 ALS2 ACL ATTACK SPEED(2) 00-03 2
17 AKBS AKB MODE 00-01 1
18 AKBP AKB PULSE HEIGHT 00-63 55
19 OSDL OSD LIMIT SELECT 00-01 0
20 MPXS UV MULTIPLEX ON 00-01 0/YUV:0
21 CXUV YC/YUV SELECT 00-01 0/YUV:1
22 UVIN U/V INVERT 00-01 0/YUV:0
23 UVOS UV OFFSET CANCELER ON 00-01 0/YUV:0
24 ACL SOFT ACL CONTROL 00-63 63
25 HBLS H BLK OFF 00-01 0
26 VENS V-latch OFF 00-01 0
27 UOFS U IN OFFSET 00-15 4
28 VOFS V IN OFFSET 00-15 9
29 AABL ANALOG ABL THRESHOLD LEVEL CONTROL 00-15 0
30 AABG ANALOG ABL GAIN CONTROL 00-01 0
31 AALG ANALOG ACL GAIN CONTROL 00-01 0
32 AABS ANALOG ABL ON/OFF CONTROL (ON:01, OFF:00) 00-01 0
33 AALS ANALOG ACL ON/OFF CONTROL (ON:01, OFF:00) 00-01 1